Rinnai EX22C User Manual

Page of 84
 
 
Rinnai Corporation EX17C / EX22C Manual 
 
  Features 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Natural Gas 
Propane Gas 
Minimum supply gas pressure 
3.5 in (89 mm) W.C. 
8.0 in (203 mm) W.C. 
Maximum supply gas pressure 
10.5 in (267 mm) W.C. 
13.0 in (330 mm) W.C. 
  Appliance Specifications
   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Natural Gas  Propane Gas 
BTU/hour input 
Low   8200 
High 16700 
Low   8200 
High 16700 
BTU/hour output  Low   6560 
High 13360 
Low   6560 
High 13360 
EX17C 
 
Natural Gas  Propane Gas 
BTU/hour input 
Low   8200 
High 21500 
Low   8200 
High 20700 
BTU/hour output  Low   6560 
High 17200 
Low   6560 
High 16560 
EX22C 
•  Restarts automatically when ignition or combustion 
fails.  
•  Clean Heating Forced Flue Type 
•  Easy Operation One-Touch Ignition 
•  Programmable Thermostat 
•  Warm Air Outlet at Floor Level (keeps your feet 
warm) 
•  Child Lock 
•  Room Temperature Setting Memory 
•  Clean the Air Filter - Indicator Lamp 
•  Energy Saving Economy Setting 
•  Humidifier Tray 
•  Air Flow Directional Louvers 
•  Direct Vent Easily Installed 
•  Proportional Heating Variable Capacity 
•  Hush! Quiet Operation 
•  Modern Design Minimizes Floor Space 
Requirements 
•  Fault Code Message Display 
•  Timers 1 and 2 
•  Dimmer 
•  Set back (setting a minimum temperature) 
•  Temperature settings in Fahrenheit or Celsius 
See the installation instructions for the parts list of 
the vent kit. 
The “A” Vent Kit is included with the appliance. 
The following flue manifold sizes are available: 
Name Kit 
No. 
Fits 
walls 
S  Vent Kit 
FOT-150 
3 - 4 1/2 in (75 - 115 mm) 
A  Vent Kit 
FOT-151 
4 1/2 - 9 1/2 in (115 - 240 mm) 
B  Vent Kit 
FOT-152 
9 1/2 - 15 3/4 in (240 - 400mm) 
C  Vent Kit 
FOT-153 
15 3/4 - 23 5/8 in (400 - 600 mm) 
D  Vent Kit 
FOT-154 
23 5/8 - 31 1/2 in (600 - 800 mm) 
  Flue Manifolds