  Gas 
Connection    
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
•  The gas supply line shall be gas tight, sized and so 
installed as to provide a supply of a gas sufficient to 
meet the maximum demand of the heater without 
loss of pressure. 
•  A shut off valve and appliance connector valve 
should be installed in the upstream of the gas line to 
permit servicing. 
•  Flexible pipe and any appliance connector valve 
used for gas piping shall be types approved by 
nationally recognized agencies. 
•  Any compound used on the threaded joint of the gas 
piping shall be a type which resists the action of 
liquefied petroleum gas (propane / LPG). 
•  After completion of gas pipe connections all joints 
including the heater must be checked for gas 
tightness by means of leak detector solution, soap 
and water, or an equivalent nonflammable solution, 
as applicable.  (Since some leak test solutions, 
including soap and water, may cause corrosion or 
stress cracking, the piping shall be rinsed with water 
after testing, unless it has been determined that the 
leak test solution is non-corrosive.) 
•  Check the gas supply pressure immediately 
upstream at a location provided by the gas 
company.  Supplied gas pressure must be within the 
limits shown in the Specifications section.   
•  Refer to an approved pipe sizing chart if in doubt 
about the size of the gas line. 
•  Install manual gas cut-off valve so that it can be 
accessed for easy operation.  Do not conceal 
manual cut-off valve behind back spacer. 
  Clearances to Combustibles 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
When determining where to install the appliance the 
clearances to combustibles shown in the figure must 
be followed.  Also refer to the Safety Behaviors and 
Practices section.  The clearance to combustibles from 
the top is zero. 
Rinnai recommends 10” (250 mm) clearance on both 
sides for servicing. 
10"(250mm)
0"
2"
      (50mm)
2"
(50mm)
40" (1m)
When connecting the gas valve or other gas 
components in the gas line, use a backup wrench to 
ensure the connection is gas tight. 
     WARNING