  Extension Kit Installation   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
If necessary, extension kits are available to extend the exhaust line and air intake hose between the manifold and 
the appliance.  The maximum vent length is 13 feet (4 m) with 2 bends.  The bent pipe attached to the appliance 
does not count toward the max limit of 2 bends.   Any length (horizontal and vertical) in excess of 8 feet (2.4 m) 
must be sloped 3° downward toward the flue manifold to allow condensate to drain to the outside.   Do not allow 
any low points in the exhaust line where condensate will collect.   
Vent extensions installed in unconditioned air space must be insulated with high temperature insulation and must 
be accessible. 
Vent extensions must not be concealed per NFPA 54 and must be accessible allowing inspection and repair.  
Decorative covers are available from Rinnai. 
Examples 
INCORRECT 
•  Too many bends (limit is 2) 
•  Air intake hose is above exhaust 
pipe 
CORRECT