Requirements 
•  Fault Code Message Display 
  Appliance Specifications
   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
The following flue manifold sizes are 
available for different wall thicknesses: 
Name Kit 
No. 
fits 
walls 
S  Vent Kit 
FOT-150 
3 - 4 1/2 in (75 - 115 mm) 
A  Vent Kit 
FOT-151 
4 1/2 - 9 1/2 in (115 - 240 mm) 
B  Vent Kit 
FOT-152 
9 1/2 - 15 3/4 in (240 - 400mm) 
C  Vent Kit 
FOT-153 
15 3/4 - 23 5/8 in (400 - 600 mm) 
D  Vent Kit 
FOT-154 
23 5/8 - 31 1/2 in (600 - 800 mm) 
 
Natural Gas 
Propane Gas 
Minimum supply gas pressure 
5.0 in (127 mm) W.C. 
11.0 in (280 mm) W.C. 
Maximum supply gas pressure 
10.5 in (267 mm) W.C. 
13.0 in (330 mm) W.C. 
BTU/hour input 
Low 10,500    High 38,400 
Low 10,500    High 36,500 
BTU/hour output 
Low 8,400      High 30,720 
Low 8,400      High 29,200 