Rinnai EX17C (RHFE-434FTA) User Manual

Page of 84
 
14 
Rinnai Corporation EX17C / EX22C Manual 
 
  Troubleshooting 
   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
  Restart 
Function    
 
 
 
 
 
 
 
 
 
 
 
 
 
 
If there is a power failure while the appliance is on, then the appliance will start automatically when the power is 
restored. 
If the appliance fails to ignite, the appliance will attempt ignition after 1 hour.  The “Ignition Failure” fault code, 11, 
will appear during that hour and disappears after a successful ignition.  If ignition fails again, then the fault code 
will remain and another attempt to ignite will occur in 1 hour.  The fault code is not stored in the fault code history.   
If the flame is extinguished during forced combustion then the appliance will attempt ignition after 1 hour.  The 
“Ignition Failure” fault code, 11, will appear during that hour and disappears after a successful ignition.  Forced 
combustion takes place for about 15 seconds before ignition.  After this time, the temperature control logic 
controls the combustion. 
If the flame is extinguished (burner combustion failure) while the temperature control logic is operating the 
appliance, then the appliance will immediately attempt ignition.  No fault code will appear. 
Problem
Remedy
Cause
Not Plugged In
Power Failure
(Initial Installation)
Air In Gas Pipe
Gas Filter Blocked
Miss Ignition
Flue terminal obstructed
Flue manifold not connected
Louver obstructed
Air filter blocked
Gas Escape
Child Lock Set
Gas turned off at meter, tank,
or valve.
Plug In
Push On/Off button to attempt
restart after power is restored.
Purge air
(Installer)
Service Call
Service Call
Clear obstruction
Service Call
Clear obstruction
Clean filter
Service Call
Cancel Child Lock
Turn gas on
No ON i
ndicator
B
urn
er doesn
’t i
gni
te
U
nus
ua
l c
ombu
st
ion
Com
busti
on s
tops
du
ring
 o
pe
rat
io
n
S
m
el
l of 
ga
s
N
oisy i
gniti
on
T
ake
too lon
g to
war
m
 the r
oom
ON Timer is set
Cancel “ON” Timer or push
override button