Rinnai EX17C (RHFE-434FTA) User Manual

Page of 84
 
24 
Rinnai Corporation EX17C / EX22C Manual 
 
  Extension Kit Installation   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
•  Extension lines are through the side panel of the 
appliance.   
•  It is not possible to position the extension lines 
through the other side panel of the appliance. 
•  One elbow is shown.  One additional elbow may be 
added.   
•  Instructions (1)-(6) must be followed. 
Plastic Tie 
Air Intake Hose 
Exhaust Line 
Pipe  
Stopper A 
Pipe Clamp 
•  Extension lines are through the top panel of the 
appliance above where the exhaust exits the appli-
ance. 
•  No elbows are shown.  Two additional elbows may 
be added. 
•  Instructions (1)-(6) must be followed. 
Plastic  Tie 
Exhaust Line 
Pipe Stopper A 
Pipe Clamp 
Air Intake Hose 
If necessary, extension kits are available to extend the 
exhaust line and air intake hose between the manifold 
and the appliance.   
(1)  The maximum vent length is 13 feet (4 m) with 2 
bends.  The bent pipe attached to the appliance 
does not count toward the max limit of 2 bends.  
(2)  Maximum vertical length allowed is 10 feet (3 m). 
(3)  If the extension is longer than 10 feet (3 m), the 
condensate may overflow the condensation pan.  
Therefore, extension exceeding this length should 
drain to the outside and sloped 3° downward. 
(4)  Do not allow any low points or sagging in the 
exhaust line.  Otherwise, condensate may block 
the exhaust and affect combustion. 
(5)  Vent extensions installed in unconditioned air 
space must be insulated with high temperature 
insulation and must be accessible. 
(6)  Vent extensions must not be concealed per NFPA 
54 and must be accessible allowing inspection and 
repair.  Decorative covers are available from 
Rinnai. 
These figures show the 2 possible ways that the 
extension exhaust line and air intake hose may be 
directed away from the appliance.  All views are from 
behind the appliance.  For your configuration, 
position the air intake hose as shown.
 
INCORRECT 
•  Too many bends (limit is 2) 
•  Air intake hose is above 
exhaust pipe