Thermo Products OH8FA119D60B User Manual

Page of 78
 
  9 
 
 
 
Fig. 7: Alternate constructions that allow reduced clearances to combustible materials. 
 
REDUCTION OF CLEARANCES WITH SPECIFIED FORMS OF PROTECTION: 
Type of protection applied to and covering all surfaces of combustible material within the distance 
specified as the required clearance with no protection unless otherwise noted, all dimensions in inches, 
refer to Fig. 7. 
 
Required clearance with no protection from the appliance or 
chimney connector is: 
 
18 inches 
9 inches 
6 inches 
Sides & 
Sides & 
Sides & 
Above Rear 
Above Rear 
Rear 
a.  3-1/2" thick masonry wall without ventilation air space…. 
--     12 
--     6 
--    5 
b.  1/2" insulation board over 1" glass fiber or mineral wool batts… 
12      9 
6    5 
4    3 
c.  0.024(24 gauge) sheet metal over 1" glass fiber or mineral 
wool batts reinforced with wire on rear face with ventilated air 
space… 
9      6 
5    3 
3    3 
d.  3- 1/2" thick masonry wall with ventilation air space.. 
--      6 
--    6 
--     6 
e.  0.024 (24 gauge) sheet metal with ventilated air space. 
9      6 
5    3 
3    2 
f.   1/2" thick insulation board with ventilation air space.. 
9      6 
5    3 
3    3 
g.   0.024 ( 24 gauge) sheet metal with ventilated air space over 
0.024 (24 gauge) sheet metal with ventilated air space…. 
9      6 
5    3 
3    3 
h.   1" glass fiber or mineral wool batts sandwiched between two 
sheets 0.024 (24 gauge) sheet metal with ventilated air space 
9     6 
5    3 
3     3 
 
A.  Equal the required clearance with no protection. 
B.  Equals the reduced clearance permitted in accordance with the preceding clearance chart. 
   C.  The protection applied to the construction that covers the combustible material should extend far enough 
in each direction to make C equal to A. 
 
The vent connector pipe between the furnace and chimney shall be of equal diameter as the flue outlet of the 
furnace.  The vent connector pipe must be made of 24 gauge (or thicker) corrosion-resistant steel.  The 
vent connector pipe should be as short as possible and installed so that it has a continuous rise from the 
furnace to the chimney. The horizontal length of a connector to a natural draft chimney or vent serving a single 
appliance shall not be more than 75 percent of the height of the vertical portion of the chimney or vent above 
the connector. Elbows should be minimized and the pipe should be joined with metal screws and supported by 
straps. All horizontal runs of vent connector pipe should be pitched upward a minimum of ¼ inch per foot of run. 
A thimble should be used to connect the vent connector pipe to the chimney so the pipe may be readily 
removed in case of inspection or replacement. See Fig. 6 on preceding page.