SETTING THE ALARM DURING FIRING 
 
After you shut off the alarm during firing, you can set it to go off again later at either a higher temperature or 
a cool-down temperature. 
 
1) While the furnace is firing, press 7 on the key board. 
2) Enter the new temperature. 
3) Press ENTER and the furnace will continue firing. 
 
 
POWER FAILURES 
 
After a brief power failure during firing, [ PF ] will display, alternating with the temperature. Even though it 
displays [ PF ], the furnace will continue to fire normally. The display shows [ PF ] simply to notify you of a 
brief power failure. Press any key except STOP and normal temperature display will return. 
 
[ ErrP ] appears after an extended power failure. In addition, after an extended power failure the controller 
will sound a steady alarm. 
 
When [ ErrP ] appears on the display, press ENTER. The hours fired and furnace temperature reached at the 
time of the power failure will be displayed. Then [ ldLE ] will display. 
 
See the “TROUBLE-SHOOTING section of your instructions for causes. 
 
 
STEAM WAX ELIMINATION 
 
We highly recommend that STEAM WAX ELIMINATION be used prior to a burnout in your furnace. This will 
remove 90% of all waxes that melt at 200 
°°°°F or less and eliminates several things. First, it eliminates carbon 
build-up on the elements of your furnace, giving it a longer life. Second, it eliminates noxious fumes and 
odors, especially from closed-in areas. There are 3 sizes of Steam Wax Eliminators available. Ask your dealer 
for more information.