Rinnai RHFE-559FTA-A-P Leaflet

Page of 2
EX22C (RHFE-559FTA)    
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us 
Safety Devices 
 
 
 
 
 
 
 
 
 
 
 
 
Venting 
Maximum Vent Length 
Wall Thickness and  
Flue Manifold Kits 
(the “A” vent kit is included  
with the appliance) 
 
 
 
 
  
Warranty 
Conversion Kit
 
•  Flame rod detects flame failure; results in auto shutdown to prevent escape 
of gas 
•  Bi-metal switch, thermal fuse, and thermistor detect overheat condition; 
results in auto shutdown 
•  3 amp fuse protects against power surge; results in auto shutdown 
•  Abnormal spark at time of ignition results in auto shutdown 
•  Combustion fan purges any gas from the combustion chamber before 
ignition 
•  Convection fan continues to run after burner shutdown to cool internal parts 
•  Child lock prevents inadvertent operation 
•  Appliance shuts down if room reaches 104° F (40° C) 
concentric; 3 1/8 inch (80 mm) wall hole 
13 feet (4 m) with a maximum of 2 bends; maximum 10 feet (3 m) vertically 
Labor: 2 years; Parts: 5 years; Heat Exchanger: 10 years  
To natural gas: 204000036 
To propane gas: 204000040 
DIMENSIONS 
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior 
notice. Local, state, provincial and federal codes must be adhered to prior to installation. 
    Name 
Kit No. 
             fits walls 
S  Vent Kit 
FOT-150 
3 - 4 1/2 in (75 - 115 mm) 
A  Vent Kit 
FOT-151 
4 1/2 - 9 1/2 in (115 - 240 mm) 
B  Vent Kit 
FOT-152 
9 1/2 - 15 3/4 in (240 - 400mm) 
C  Vent Kit 
FOT-153 
15 3/4 - 23 5/8 in (400 - 600 mm) 
D  Vent Kit 
FOT-154 
23 5/8 - 31 1/2 in (600 - 800 mm) 
10.1 in (257 mm) 
3.3 in 
(85 mm) 
6.8 in 
(172 mm) 
 
 
29.9 in (760 mm)
22.9 in