Goodman Mfg GMV95/GCV9 User Manual

Page of 16
4 www.goodmanmfg.com 
SS-GMV95
P
RODUCT
 S
PECIFICATIONS
GMV95 D
IMENSIONS
M
INIMUM
 C
LEARANCES
 
TO
 C
OMBUSTIBLE
 M
ATERIALS
Position
Sides
Rear
Front
Bottom
Flue
Top
Upfl ow
0”
0”
3”
C
0”
1”
Horizontal
6”
0”
3”
C
0”
6”
C = If placed on combustible fl oor, the fl oor MUST be wood ONLY.
Notes:
•  For servicing or cleaning, a 24” front clearance is required.
•  Unit connections (electrical, fl ue and drain) may necessitate greater clearances than the minimum clearances listed above.
•  In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clear-
ances are greater.
Model
A
B
C
D
E
GMV950453BXB
17½”
16”
13⅛”
12⅛”
13⅝”
GMV950704CXB
21”
19½”
16⅛”
16
17½”
GMV950905DXB
24½”
23”
20⅝”
19⅜”
20⅞”
GMV951155DXB
24½”
23”
20⅝”
19⅜”
20⅞”
Notes:
•  Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the fl ue outlet (required). Vent pipe must be 
either 2” or 3” in diameter, depending upon furnace input, number of elbows, length of run and installation 
(1 or 2 pipes). The optional Combustion Air Pipe is dependent on installation/code requirements and must be 2” or 3” diameter PVC.
•  Line voltage wiring can enter through the right or left side of the furnace. Low-voltage wiring can enter through the right or left side of 
furnace.
•  Conversion kits for high-altitude natural gas operation are available. Contact your Goodman distributor or dealer for details.
•  Installer must supply following gas line fi ttings, according to which entrance is used:
Left
—Two 90º elbows, one close nipple, straight pipe
Right
—Straight pipe to reach gas valve
•  For bottom return: Failure to unfold fl anges may reduce airfl ow by up to 18%. This could result in performance and noise issues.