The normal operational sequence in heating mode is as fol-
lows:
lows:
•
R and W1 (or R and W1/W2) thermostat contacts close,
initiating a call for heat.
initiating a call for heat.
•
Integrated control module performs safety circuit checks.
•
Induced draft blower is energized on high speed for a 15-
second prepurge. Humidifier terminal is energized with
induced draft blower.
second prepurge. Humidifier terminal is energized with
induced draft blower.
•
Induced draft blower steps to low speed following
prepurge. Low stage pressure switch contacts are
closed.
prepurge. Low stage pressure switch contacts are
closed.
•
Igniter warm up begins upon step to low speed and
presence of closed low stage pressure switch contacts.
presence of closed low stage pressure switch contacts.
LED LED
Status
Indication
Possible Causes
Corrective Action(s)
Notes & Cautions
Off
x Normal condition
x None
x None
x None
1 Flash
x Communications
Failure
x Communications
Failure
x Depress Learn Button
x Verify that bus BIAS
x Verify that bus BIAS
and TERM
dipswitches are in the
ON position.
dipswitches are in the
ON position.
x Depress once
quickly for a power-
up reset
up reset
x Depress and hold
for 2 seconds for
an out-of-box reset
an out-of-box reset
Red
Communications
LED
2 Flashes
x Out-of-box reset
x Control power up
x Learn button
x Learn button
depressed
x None
x None
Off
x No power
x Communications
x Communications
error
x No power to furnace
x Open fuse
x Communications error
x Open fuse
x Communications error
x Check fuses and
circuit breakers;
replace/reset
replace/reset
x Replace blown fuse
x Check for shorts in
x Check for shorts in
low voltage wiring in
furnace/system
furnace/system
x Reset network by
depressing learn
button
button
x Check data 1/ data 2
voltages
x Turn power OFF
prior to repair
1 Steady
Flash
x No network found
x Broken/ disconnected
data wire(s)
x Furnace is installed as
a legacy/ traditional
system
system
x Check
communications
wiring (data 1/ data 2
wires)
wiring (data 1/ data 2
wires)
x Check wire
connections at
terminal block
terminal block
x Verify furnace
installation type
(legacy/ traditional or
communicating)
(legacy/ traditional or
communicating)
x Check data 1/ data 2
voltages
x Turn power OFF
prior to repair
x Verify wires at
terminal blocks are
securely twisted
together prior to
inserting into
terminal block
securely twisted
together prior to
inserting into
terminal block
x Verify data1 and
data voltages as
described above
described above
Rapid
Flashing
x Normal network
traffic
x Control is “talking” on
network as expected
x None
x None
Green Receive
LED
On Solid
x Data 1/ Data 2
miss-wire
x Data 1 and data 2
wires reversed at
furnace, thermostat,
or CT™ compatible
outdoor AC/HP
furnace, thermostat,
or CT™ compatible
outdoor AC/HP
x Short between data 1
and data 2 wires
x Short between data 1
or data 2 wires and R
(24VAC) or C (24VAC
common)
(24VAC) or C (24VAC
common)
x Check
communications
wiring (data 1/ data 2
wires)
wiring (data 1/ data 2
wires)
x Check wire
connections at
terminal block
terminal block
x Check data 1/ data 2
voltages
x Turn power OFF
prior to repair
x Verify wires at
terminal blocks are
securely twisted
together prior to
inserting into
terminal block
securely twisted
together prior to
inserting into
terminal block
x Verify data1 and
data voltages as
described above
described above
N
ORMAL
S
EQUENCE
OF
O
PERATION
P
OWER
U
P
The normal power up sequence is as follows:
•
115 VAC power applied to furnace.
•
Integrated control module performs internal checks.
•
Integrated control module displays
88888 88888 on dual 7-segment
display LED’s.
•
Integrated control module monitors safety circuits
continuously.
continuously.
•
Furnace awaits call from thermostat. Dual 7-segment
LED’s display
LED’s display
00000 PPPPP while awaiting call from thermostat.