Introduction
Always  consult  your  local  Building  Department  regarding 
regulations, codes or ordinances which apply to the installation of 
a direct vent wall furnace.
Instructions to Installer
1.  Installer  must  leave  instruction  manual  with  owner  after 
installation.
2.  Installer must have owner fill out and mail warranty card supplied 
with furnace.
3.  Installer should show owner how to start and operate furnace 
and thermostat.
4.  Installer must locate unit near a grounded wall receptacle for 
115VAC power and must provide gas supply and vent the unit 
properly for safe operation.
Warning:
Any change to this furnace or its control can be dangerous.  
This is a heating appliance and any panel, door or guard 
removed for servicing an appliance must be replaced prior 
to operating the appliance.
General Information
This series is design certified in accordance with American National 
Standard / CSA Standard Z21.86 and CSA 2.32 by the Canadian 
Standards Association as a Fan Type Direct Vent Wall Furnace to 
be installed according to these instructions.
Any  alteration  of  the  original  design,  installed  other  than 
as shown in these instructions  or use with a type of gas not 
shown on the rating plate is the responsibility of the person and 
company making the change.
Important
All correspondence should refer to complete Model Number, Serial 
Number and type of gas.
Notice:  During initial firing of this unit, oil from the heat exchanger 
may bake out  and smoke may occur.  To prevent triggering of smoke 
alarms, ventilate the room in which the unit is installed.
Installation in Residential Garages
Gas utilization equipment in residential garages shall be installed 
so that all burners and burner ignition devices are located not less 
than 18" (457mm) above the floor.
Such equipment shall be located, or protected, so it is not subject 
to physical damage by a moving vehicle.  
Qualified Installing Agency
Installation and replacement of gas piping, gas utilization equipment 
or  accessories  and  repair  and  servicing  of  equipment  shall  be 
performed only by a qualified agency.  The term "qualified agency" 
means any individual, firm, corporation or company which either in 
person or through a representative is engaged in and is responsible 
for  (a)  the  installation  or  replacement  of  gas  piping  or  (b)  the 
connection, installation, repair or servicing of equipment, who is 
experienced in such work, familiar with all precautions required 
and has complied with all the requirements of the authority having 
jurisdiction.
State  of  Massachusetts:  The  installation  must  be  made  by 
a  licensed  plumber  or  gas  fitter  in  the  Commonwealth  of 
Massachusetts.
The installation must conform with local codes, or in the absence 
of local codes, the National Fuel Gas Code, ANSI  Z223.1/NFPA 
54 or Natural Gas and Propane Installation Code, CSA B149.1. 
*Available from the American National Standards Institute, Inc., 
11 West 42nd St., New York, NY 10036.
A manufactured home (USA only) or mobile home OEM  installation 
must conform with the Manufactured Home Construction and Safety 
Standard, Title 24 CFR, Part 3280, or, when such a standard is not 
applicable, the Standard for Manufactured Home Installations, ANSI 
Z225.1, or Standard for Gas Equipped Recreational Vehicles and 
Mobile Housing, CSA Z240.4.
High Altitudes
For altitudes/elevations above 2,000 feet (610m), input ratings should 
be reduced at the rate of 4 percent for each 1,000 feet (305m) above 
sea level, this may be accomplished by reducing manifold pressure.  
The maximum allowable reduction in manifold pressure for Natural 
gas shall be from 3.5" w.c. (.872kPa) to 2.8" w.c.  (.697kPa).  The 
maximum allowable reduction in manifold pressure for Propane 
(LP) gas shall be from 10.0" w.c. (2.49kPa) to 8.0" w.c. (1.99kPa). 
For Canadian high altitude applications, this appliance is suitable 
for installation at elevations between 0 feet (0m) and 4,500 feet 
(1,372m) without change. 
Model
DV-55E
Input BTU/HR (KW/H)
55,000 (16.1)
Height
26" (660mm)
Width
37" (940mm)
Depths with Shroud
15 3/4" (400mm)
Gas Inlet (Pipe)
1/2" (13mm)
Electrical - Unit has a 5' (1.5m) 3 pronged cordset for connec-
tion  to  an  approved  115  VAC  60HZ  maximum 
AMPs - 5A wall receptacle.
Accessories for DV-55E Furnaces
Extended Vent Terminal
    For walls up to 32" (813mm)
DVT-2
Floor Pad
DVP-1
INTRODUCTION
SPECIFICATIONS