Empire Products DV-25T-1 User Manual

Page of 20
13117-9-0907
Page 9
Installing Wall Mounting Bracket
Locate and cut wall opening.  If there is insulation above the wall open-
ing (air inlet tube) a barrier should be installed above the wall opening 
(air inlet tube) to prevent insulation from coming in contact with the air 
inlet tube.  The barrier must not penetrate into the 7 1/2" diameter wall 
opening.  Place the flat surface of the wall mounting bracket toward the 
wall.  Insert half round flange of wall mounting bracket into and at the 
top of the wall opening.  Level the wall mounting bracket in the wall 
opening.
On solid wall, when using wall studs for attachment of wall mounting 
bracket, fasten wall mounting bracket to wall studs with two (2) 10 x 1 
1/2" screws and fasten two (2) additional 10 x 1 1/2" screws through the 
wall mounting bracket and into the solid wall.
On sheet rock wall, when using wall studs for attachment of wall 
mounting bracket, fasten wall mounting bracket to wall studs with four 
(4) 10 x 1 1/2" screws or four (4) plastic expansion anchors.
On Sheet Rock Wall Using Plastic Expansion Anchors
1.  After  locating  mounting  holes,  drill  four  (4)  5/16"  diameter  holes 
into the wall.
2.  Insert four (4) plastic expansion anchors provided into the holes.
3.  Tighten four (4) #10 x 1" screws provided into the plastic expansion 
anchors (See Figure 6).
Attaching Furnace to Wall Mounting Bracket
1.  Remove casing front from furnace.
2.  Lay furnace face-down on a non-abrasive work surface.
3.  Place collar on four inch flue tube against combustion camber back.  
Align  clearance  holes  on  collar  with  screw  holes  in  combustion 
chamber.  Attach four inch flue tube against combustion chamber 
with four (4) 10 x 1/2" screws.
4.  Place collar on six inch air tube against inlet air drop chute.  Align 
clearance holes on collar holes with screw holes in inlet air drop 
chute.  Attach six inch air tube to inlet air drop chute with eight (8) 
10 x 1/2" screws.
5.  When facing the furnace, the two (2) clearance holes for attaching 
the  furnace  to  the  wall  mounting  bracket  are  located  beneath  the 
casing top and above the combustion chamber.
6.  Insert  tubes  through  wall  opening  as  you  hang  the  furnace  on 
the  wall  mounting  bracket  by  aligning  two  *2)  tabs  on  the  wall 
mounting  bracket  with  two  (2)  slots  located  on  inner  casing  top.   
Attention: You must support the weight of the furnace until the fur-
nace is attached to the wall mounting bracket.
7.  Attach  furnace  to  wall  mounting  bracket  with  two  (2)  10  x  1/2" 
screws.  
Attention: You will need a 5/16" socket with a 10" - 12" 
extension to attach furnace to wall mounting bracket.
8.  The inner casing bottom is to be fastened to the wall.  On solid wall, 
fasten inner casing bottom with two (2) 10 x 1 1/2" screws.  On 
sheet rock wall, fasten inner casing bottom with two (2) plastic ex-
pansion anchors.
Figure 5
Figure 6
INSTALLATION INSTRUCTIONS (continued)