12431-7-0107
4.  Apply  furnace  cement  to  4"  diameter  flue  outlet  collar  on 
combustion chamber and to 4" diameter collar on vent cap. 
Attach 4" diameter flue outlet tube onto flue outlet collar on 
combustion chamber. Attach vent cap into the 4" diameter flue 
outlet tube. Attach vent cap to outside mounting plate with (3) 
#10 x 1/2" screws provided.
5.  Reassembly and resealing vent-air intake system is completed.
Installing a Vent Near a Window Ledge, 
Other Type of Projection or on Siding (vinyl, aluminum, etc.)
Direct  vent  furnaces  are  designed  to  be  installed  on  a  uniform 
outside wall. When the wind comes from any angle (up, down or 
from either side), it must hit the vent cap equally over both the air 
inlet and the flue outlet portions of the vent. Any wall projection, 
such as a door or window casing, which disturbs the wind on one 
side of the air inlet section will result in back pressure on the flue 
section smothering the flame and eventual pilot outage.
When the vent cap is to be installed on siding or it appears that a 
projection within 6" of any side of the air inlet section could shield 
the air inlet section, the entire vent should be supported away from 
the wall at least the distance of the projection. 2" x 4" framing 
whose  outside  dimensions  match  the  overall  dimensions  of  the 
mounting plate is recommended. The 2" x 4" framing protects sid-
ing from possible warpage or discoloration. All joints can then be 
sealed and painted. The wall depth plus the additional depth of the 
2" x 4" framing should not exceed a total depth of 13" for DV-55. 
(See Figure 9)
Vinyl siding vent kit, DV-822, is available from Empire Comfort 
Systems, Inc. The depth is 3", which enables the vent cap to be 
extended away from siding or projections. The wall depth plus the 
additional 3" depth of the vinyl siding vent cap extension should 
not exceed a total depth of 13" for DV-55.  (See Figure10)
Warning: When vinyl siding vent kit, DV-822 or 2" x 4" 
framing  is  added  to  an  existing  installation  (furnace  is 
installed) do not attempt to add sections of pipe to the flue 
outlet tube or air inlet tube. An air tight seal is required for 
both tubes. Refer to Parts List, page 16 to order tubes.
Figure 9 
Figure 10
INSTALLATION INSTRUCTIONS (continued)