Windsor ADM8 10080170 User Manual

Page of 42
MAINTENANCE 
ADMIRAL 86038230   
4-3 
3
8
 [9.5 mm]
Carbon 
Brushes
End Cap
If armature commutator is grooved, extremely pitted or not
concentric, the motor will need to be replaced or sent to a 
qualified service center.
Important:
These brushes wear quicker as the length shortens due to
increased heat.  Spring inside brush housing will damage 
motor if brushes are allowed to wear away completely.
Periodically check the length of the carbon brushes.  Replace 
both carbon brushes when either is less than 3/8" (9.5mm)
long.
WARNING: The green ground wire must be attached for
safe operation.  See wiring diagram.
AVERTISSEMENT: Le fil à la terre vert doit être attaché
pour un fonctionnement en toute sécurité. voir le schéma
de câblage.
 
Only qualified maintenance personnel are to perform the following repairs. 
 Seul le personnel d'entretien qualifié peut effectuer des réparations.
 
VACUUM MOTOR REPLACEMENT 
1.  Turn off all switches and unplug machine. 
2. Remove 
recovery 
tank. 
3.  Remove the (2) screws that fasten the solution tank to 
the frame, and tilt tank back to expose the inside of the 
frame. 
4.  Locate the vacuum motor wires and disconnect at the 
connector. Close the solution tank. 
5.  Remove the (6) screws holding the vacuum motor cover 
(p/n 27809) to the solution tank. 
6.  Remove the vacuum motor. 
7.  Reverse process to install vacuum motor.