Sterling 350-2100 CFM User Manual

Page of 58
350-2100 cfm Dryers 
Chapter 5: Startup, Shutdown & Operation 
32 of 58 
 
•  Press 
 again to move one digit to the right. Then press 
 to display the 
desired value. 
•  Follow this procedure to set all four digits. 
•  When satisfied with the value displayed, press 
 to save the new value to the 
regeneration monitor's memory, and move on to the next parameter, if desired. 
•  Press 
 repeatedly to review the new settings. 
 
5-12  Auxiliary Process Safety System (Optional) 
 
This option provides an extra level of protection from hopper meltdown due to a runaway heat 
condition such as a fused heater contactor. When triggered, this system will drop out high voltage to all 
heater contactors and blowers. This drastic action, to protect the resin and the drying hopper, will only 
occur if a high temperature condition is not first handled by the ¼ DIN control [Section 4-1] on the 
dryer subpanel and/or the heater contactor(s) is/are fused.    
This system must be manually reset by pressing the OVERTEMP RESET button after fixing the 
problem. 
 This option uses a signal processor identical to the one used in the regeneration monitoring system. It 
monitors the process temperature through a thermocouple mounted at the drying hopper inlet.  Only one 
of the setpoints [H] is used. See Section 5-11 for instructions on setting the H setpoint.    
The H setpoint should be the highest temperature tolerable at the drying hopper, before resin or drying 
hopper degradation occurs.  This temperature varies depending on the resin and the drying temperature, 
but a suggested starting temperature is 75
°F above the drying temperature. 
 
5-13  Seven Day Timer (Optional) 
The seven day timer can be programmed for weekly ON/OFF operation of up to sixteen setpoints. An 
internal battery back-up holds the settings in memory when the dryer is de-energized.  
The dryer's Power toggle switch must be in the "ON" position for normal or programmed dryer 
operation.  
 
•  To bypass programmed operation, switch the manual override switch on the 
seven day timer to the "ON" position. 
•  To execute programmed operations, set the manual override switch on the seven 
day timer to the "RUN" position. 
•  To de-energize the seven day timer, set the manual override switch to the "OFF" 
position.  
 
The dryer will not run if the timer switch is "OFF".  
Program 1 is operational, Program 2 is not used.