Amcor SD12 User Manual

Page of 12
10
Model
SD12
Power supply
220-240 V/ 50 Hz
Power consumption 
(at 32 °C, RH 90%)
W
235
Current
A
1.3
Moisture removal 
(at 32 °C, RH 90%)
L/24h
12
Refrigerant
R-134A
Refrigerant load
g
170
Water container capacity
L
4
Operating temperature range
°C
5 - 35
Dimensions
(width x depth x height)
mm
420 x 220 x 540
Net weight
kg
15
Subject to modifi cation without prior notice. For greater precision, please refer to the rating label placed on the product.
GB
 TROUBLE 
SHOOTING
TECHNICAL DATA
Never try to repair or dismantle the unit yourself. Before calling for assistance please check 
the points below.
The unit doesn’t run.
Is the machine plugged in?
Is the mains power supply on?
Is the water tank full indicator on? (If so, the water tank is full or it isn’t 
positioned properly).
The unit seems to 
extract little water.
Are too many windows or doors open?
Is there something in the room producing lots of heat?
Is the room cold – the colder the air the less moisture the unit will extract.
Is the filter dirty?
Is the room humidity already quite low? 
The unit seems to do 
nothing.
Is the filter dirty?
Is the air intake or outlet blocked?
Is the room humidity already quite low?
Is the room temperature below 5 °C? The fan may run without the compressor.
Too noisy.
Is the machine positioned unevenly so as to create vibration?
Is the floor underneath the unit uneven or loose fitting?
Is there any foreign body interfering with the unit?
The unit’s fan doesn’t 
seem to be revolving.
Is the filter blocked?
Is there any foreign body interfering with the unit?
The continuous 
drainage is not working.
Does the hose have a downward slope throughout its entire length?
Is there a kink or sharp bend in the hose?