Aprilaire 3310 User Manual

Page of 4
Media Air Cleaners  
Installation Instructions
1.  High voltage may cause serious 
injury from electrical shock. 
Disconnect power to the  
furnace/air handler before 
starting installation.
2.  Sharp edges may cause injury 
from cuts. Use care when cutting 
and handling sheet metal.
 WARNING
1.  To prevent component failure, do not install the air cleaner on the warm 
air supply or in an area where the temperature may exceed 140°F. This 
may include areas above heat exchangers in downflow furnaces or above 
exhaust flues in lowboy furnace cold air returns.
2.  Installation must be done by a qualified heating and air conditioning 
professional. Read instructions thoroughly before beginning installation.
3.  Do not install air cleaner downstream of a UV light. UV lamps will cause 
degradation of the filtering media.
 CAUTION
SPECIFICATIONS
Airflow Capacity: up to 2000 CFM maximum
Replacement Media:  
   1210, 2210, 3210: Model 210 or 213 with SelfSeal
 
   1310, 2310, 3310: Model 310 or 313 with SelfSeal
™ 
   1410, 2410, 3410: Model 410 or 413 with SelfSeal
™ 
Max. Equipment Weight:  
   
Cabinet will support 400 lb. static load
Air Cleaner Operating Environment:  
   Temperature: 0°F – 140°F 
   Humidity: 0-90% non-condensing
DIMENSIONS
TABLE 1 – Dimensions (inches)
Model
A
B
C
D
E
F
G
H
1210, 2210, 3210
19-3/4
25-3/8
21-3/16
6-3/4
27-3/8
21-3/16
19-3/4
22-1/16
1310, 2310, 3310
18-1/16
20-1/16
15-7/8
6-3/4
22-1/16
15-7/8
18-1/16
20-3/8
1410, 2410, 3410
15-7/16
28-1/16
23-7/8
6-3/4
30-1/16
23-7/8
15-7/16
17-3/4
A
B
without door
C
D
with door
F
G H
90-1333