ZyXEL Communications 2110 User Manual

Page of 22
 Chapter 4 SHD2110/3110 Programming
Z-Wave Series Programming Guide
17
4.2  Z-Wave Groups (Association Command Class Version 2)
On the Z-Wave Controller, you can set the SHD2110/3110 to send its latest status (including power, 
switch binary, and meter report) to associated nodes of Grouping 1 or control associated Z-Wave 
devices of Grouping 2. Grouping 1 supports one node and Grouping 2 supports up to four nodes. 
4.2.1  Grouping 1
Grouping 1 includes the following commands: POWER_APPLIEDSWITCH_BINARY_REPORT
and METER_REPORT_COMMAND.
4.2.1.1  POWER_APPLIED command
When the SHD2110/3110 is properly connected to a wall outlet, the ALARM_REPORT command 
will be sent to Grouping 1 to inform that the SHD2110/3110 is powered up. 
4.2.1.2  On/Off Event Report (True State)
When you toggle the On/Off button on the SHD2110/3110, the Switch Binary Report is sent to 
Grouping 1. However, if a specified period of time (the "true period") is set (
), toggling the On/Off button will not send Switch Binary Report instantly. 
When you initially press the On/Off button, the SHD2110/3110 is locked until the preset true period  
is over. As soon as the true period is over and the SHD2110/3110 is unlocked, the device will check 
if the current state is different from the initial state. If it is different, the SHD2110/3110 will send 
Switch Binary Report to Grouping 1 immediately; whereas if it is the same, the SHD2110/3110 
will not send the report to Grouping 1.
You can set the true period through configuration command class. Refer to the true period of 
configuration.
4.2.1.3  Binary Switch Report Command
[Command Class Switch Binary, Switch Binary Set, Value = (255)0xFF]: the load 
attached to the Module turns on.
[Command Class Switch Binary, Switch Binary Set, Value = 0(0x00)]: the load 
attached to the Module turns off.
ALARM_REPORT Command
[Command Class Alarm, Alarm Type = 0x02, Alarm Level = 0x01]
ON
[Command Class Switch Binary, Switch Binary Report, Value =(255)0xFF]
OFF
[Command Class Switch Binary, Switch Binary Report, Value =0(0x00)]