13
 
Operation 
Front Panel Display and Controls 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
General Operation 
Once the HGMSZ has been installed, set up, and powered ON, it will make measurements in the area 
being sampled for refrigerant gas without further operator intervention. The results of those 
measurements are displayed on the front panel display.  
 
 
 
In the example shown above, MEASURE indicates that the HGMSZ is actively monitoring for refrigerant 
gas, and that currently 45 ppm of R-134a gas is being detected. This display also indicates that a peak 
measurement of 485 ppm has been made.  
An operator can reset the peak value to zero by pressing the ENTER button. 
A log of up to 200 previous measurements can be viewed using the PPM LOG screen (Page 15). 
If the detected gas level exceeds the preset Leak, Spill, or Evacuate alarm point, then the monitor 
responds by turning ON the front panel ALARM (red) light and energizing the corresponding alarm relay. 
If the internal audible alarm is turned ON, it too will activate. Optional external alarm devices can be 
connected to the alarm relays to alert personnel that a Leak, Spill, or Evacuate alarm condition has 
occurred. Pressing the front panel SILENCE button will acknowledge an alarm and turn OFF all alarm 
indicators. The alarm circuit will reactivate, however, if the alarm condition is not cleared within the time 
period set by the SILENCE function (Page 16). 
MONITOR
ON
SYSTEM
FAULT
ALARM
ENTER
HGMSZ
HALOGEN GAS MONITOR SINGLE ZONE
SILENCE / QUIT
DISPLAY 
SCREEN
ENTER 
Press to save a 
displayed value
KEYPAD 
Use these buttons: 
1) To move the arrow 
(>) on the display 
screen to the desired 
function 
2) Scroll through data 
3) Change a 
function’s value 
MONITOR ON 
LIGHT (Green) 
Flashes during 
warm-up 
SYSTEM FAULT 
LIGHT (Yellow)
ALARM LIGHT 
(Red)
SILENCE / QUIT 
Press this button: 
1) To acknowledge 
an alarm and turn 
OFF the Alarm Light
2) Return to the 
previous screen 
without saving data 
MEASURE  00485pk 
   45ppm R134A