Bacharach 19-9336 User Manual

Page of 4
Combustible Gas Leak Detector
Instruction 19-9336
Rev. 0 – October 2005
Audible Alarm
•  Instrument Ready - Slow beep. The beep
rate is about once per second with no gas
detected.
•  Combustible Gas Indication - Beeps at
a rate that increases along with the gas
concentration.
•  Sensitivity - Produces an increasing
frequency tone when sensitivity changes
from low to high, and produces a decreasing
frequency tone when sensitivity changes
from high to low.
•  Dead Batteries - High frequency tone, fol-
lowed by the instrument turning itself OFF.
•  Sensor Error - Rapidly changing high and
low frequency tones.
Visual Alarm LED
•  Power ON - 
Rapidly flashes green during warm-
up (approximately 60 seconds).
•  Power OFF - Glows red just before power OFF.
•  Instrument Ready -
 Slowly flashes green. The 
flash rate is about once per second with no gas 
detected.
•  Combustible Gas Indication - Flashes green at
a rate that increases with the gas concentration.
•  Sensitivity Change - Color changes from red to
green.
•  Low Battery - Flashes orange instead of green
when checking for gas leaks. Typically 1 hour
of operation left after LED changes to orange.
Change batteries as soon as convenient.
•  Dead Batteries - Glows red, followed by the
instrument turning itself OFF.
•  Sensor Error - Flashes alternating green and red.
One Button Control
•  Press once for half second to turn instrument ON.
•  Press and hold for 2 seconds to turn instrument OFF.
•  Double press to toggle sensitivity between high and low.
Combustibles Sensor 
& Sensor Cover
Battery Door
12 Inch
Flexible Probe