Bacharach 24-9351 User Manual

Page of 100
PCA
Instruction 24-9351
4-16
Operation
TABLE 4-2.  TYPICAL SPREADSHEET FOR A PCA 65
Line 1: Column Headings
Line 2: Typical Combustion Readings
Line 3: Typical Draft Reading
SN
ID1
ID2
ID3
TIME
DATE
FUEL
TA
TL
C/F
O2
AX1020
ID  LINE 1
ID LINE 2
ID LINE 3 9:03:27 19.01.1999
NATGAS
190
20
C
4
AX1020
ID  LINE 1
ID LINE 2
ID LINE 3 9:10:35 19.01.1999
C2
CO
CU
NX
NU
qA
LA
DR
MB/PA/WC
9.5
 12
15
 10
 12
8.1
1.24
-0.25
MB
-0.25
MB
TABLE 4-1.  COMMA-DELIMITED FIELDS
Field
Data Name or Value
Label in Column
Headings
1
Instrument serial number
SN
2
ID line 1 (up to 16 characters)
ID1
3
ID line 2 (up to 16 characters)
ID2
4
ID line 3 (up to 16 characters)
ID3
5
Time of test (hh:mm:ss)
TIME
6
Date of test (dd.mm.yyyy)
DATE
7
1
Name of fuel (up to 16 characters)
FUEL
8
1
Flue gas temperature
TA
9
1
Air temperature
TL
10
1
Temperature unit of measure (F or C)
C/F
11
1
O
2
 
concentration in %
O2
12
1
CO
2
 concentration in %
C2
13
1,2
CO concentration in ppm
CO
14
1,2
CO referenced to 0% O
2
 in ppm
CU
15
1,3
NO concentration in ppm
NX
16
1,3
NO referenced to 0% O
2
 in ppm
NU
17
1
qA in %
qA
18
1
Lambda
LA
19
Draft measurement
DR
20
Draft unit of measure
MB/PA/WC
1
Empty data field for draft tests
2
Empty data field for PCA Models 40 and 45
3
Empty data field for PCA Models 40, 45, 50, and 55