Door Edge and Photoelectric Wiring 
INSTALLATION INSTRUCTIONS  
14 
After properly connecting an approved Entrapment Protection Device (see above and Page 3) to the operator, see Page 17 for 
setting of the selector switches.  These switches must be properly set and an approved photoelectric device or approved door 
edge device connected to the operator to obtain B2 Mode of Operation, Momentary Contact to Close. 
Linear Approved 
Photoelectric 
Entrapment 
Protection Device 
See 
Note A above 
Emitter 
Part # 
217792 
Detector 
Part # 
217800 
3 Wire Photoelectric Entrapment 
Protection Device wiring. Note: This device can be used for 
additional Entrapment protection but connection of this device 
will not enable the Momentary Contact to Open Mode. 
Any Miller Edge ME, MT/MU, and CPT 
family of edges, must be connected to the 
SM-102 Edge Module, Recognized by UL 
as per UL325 2010 on 08-29-2010. 
See 
Note A to the left. 
2 Wire Door Edge 
Protection Device wiring. Note: This device can be used for 
additional Entrapment protection but connection of this device 
will not enable the Momentary Contact to Open Mode. 
Note A:  
Connect only 
one (1)
 approved entrap-
ment protection device to terminals “Photo” and 
“Com”.  If additional entrapment protection is desired 
connect additional photoelectric and door edges devices 
to “NC REV”, “NO REV” and “COM” terminals as 
shown here. 
Note: When adding a photocell device with a 
Normally Closed output remove the factory 
installed jumper from the connection terminals. 
OP
E
N
TB1
STOP
CLOSE
OPEN
CO
M
CLOS
E
STO
P
NO RE
V
NC 
R
E
V
PHOT
O
CO
M
SIN
G
L
E
ILO
C
K
24
 V
A
C
CO
M
SAFE FINISH PHOTOBEAM
3-WIRE PHOTOBEAM
 
ENTRAPMENT PROTECTION DEVICES WIRING INSTRUCTIONS