Linear AUH-S User Manual

Page of 26
Changing the Switch Selectable Operation Modes 
The following modes are selected by setting the on-board dip 
switches, Figure 20 at right shows where the switches are 
located on the operator control board. For each Operational 
Mode, the switches are set to either ON or OFF according to the 
table at right below. For all the modes, if an approved  
entrapment protection (EP) reversing device as described on 
page 3 of this manual is attached to the input labeled “Photo”, it 
will function as noted.  Once an approved EP device is 
recognized by the control board it is monitored for correct 
operation.   If the device becomes inactive then the mode will 
default to constant pressure activation for close regardless of the 
dip switch setting.  In order for any of the Momentary Contact to 
Close operation modes (B2, TS, T) to become active an 
approved Entrapment Protection (EP) Reversing device (see 
Page 3) must be properly installed and connected to the operator.  
The switches must be set to one of the six Operational Mode 
combinations for the operator to function. In order for the NO 
(Normally Open) Reverse or NC (Normally Close) Reverse 
inputs to function, you must first install an operational approved 
Entrapment Protection (EP) Reversing Device. 
 
B2 Operation (Factory Default) 
Open Button: Momentary activation; open override of closing 
door. 
Close Button: Momentary activation. 
Stop Button: Momentary activation; stops open, close or reverse 
action. 
Single Button: Momentary activation to open; open override of 
closing door, closes door from mid-stop or open limit. 
EP Reverse (Photo Input): Momentary activation will reverse a 
closing door, reverse to full open (ignores mid-stop) unless 
stopped by stop pushbutton input. 
Mid-Stop: Activation stops an opening door; momentary contact 
of open button at mid stop will restart door to full open position; 
if door is moving open, constant pressure on open button will 
bypass mid-stop. 
Auto Close Timer: N/A. 
 
C2 Operation  
Open Button: Momentary activation; open override of closing 
door. 
Close Button: Constant activation, door will stop when button is 
released. 
Stop Button: Momentary activation; stops open, close or reverse 
action. 
Single Button: Momentary activation to open; open override of 
closing door. 
EP Reverse (Photo Input): Momentary activation will reverse a 
closing door, reverse to full open (ignores mid-stop) unless 
stopped by stop pushbutton input. 
Mid-Stop: Activation stops an opening door; momentary contact 
of open button at mid stop will restart door to full open position; 
if door is moving open, constant pressure on open button will 
bypass mid-stop. 
Auto Close Timer: N/A. 
 
D1 Operation 
Open Button: Constant activation; open override of closing door. 
Close Button: Constant activation, door will stop when button is 
released. 
Stop Button: Momentary activation; stops open, close or reverse 
action (not required). 
Single Button: N/A. 
EP Reverse (Photo Input): Momentary activation will stop a 
closing door. 
Mid-Stop: Activation stops an opening door; after the door stops 
at the mid stop, constant contact of open button at mid stop will 
restart door to full open position. 
Auto Close Timer: N/A. 
 
E2 Operation (roll-back) 
Open Button: Momentary activation; open override of closing 
door. 
Close Button: Constant activation, door will reverse to full open 
(ignores mid-stop) when button is released. 
Stop Button: Momentary activation; stops open, close or reverse 
action. 
Single Button: N/A. 
EP Reverse (Photo Input): Momentary activation to reverse a 
closing door, reverse to full open (ignores mid-stop) unless 
stopped by stop pushbutton input. 
 
C
D
OM
C
B
 2
00
5
EDGE
RADIO
c.
p.
 ALL
ST
A
CO
RP
.
P4
24V
S1
R58
R56
R55
R54
R45
R46
R53
P
C
11
26
95
 R
E
V
 B
 T
S
L
K
K2
K4
K3
K5
K6
C
O
M
OL
S
CL
S
C
O
M
HIGH VOLTAGE
OPE
N
MO4
MO3
MO2
MO1
ILK
24V
COM
VCC
FRA
COM
24V
RM1
RM2
RM3
VCC
COM
P7
R8
R24
C12
TB1
STATUS
LD4
OFF
S4
S3
S2
S1
C25
R94
R87
R38
R22
R10
P5
PB1
PB2
PB3
R49
C6
R93
R90
U5
R62
R61
R60
R5
R25
R9
R23
R51
R19
R17
R13
R20
R18
R14
STOP
CLOSE
OPEN
R7
R6
R16
R15
R11
R12
POWER
C24
R85
U1
C2
RO
1
D8
U4
C1
1
R3
0
R2
6
R2
9
C3
C1
C8
R47
R84
R95
SW1
R83
R82
R33
R34
R2
R3
R4
C21
R21
D2
R65
C10
D3
C9
TR4
TR2
R52
C14
TR1
R48
C13
TR3
R89
Q1
C7
D1
D12
R28
R27
C16
LD3
LD2
P2
P3
R1
C30
P1
R31
P6
R57
COM
CL
OS
E
STOP
NO 
R
E
V
NC 
RE
V
PH
OTO
COM
SING
L
E
IL
OCK
2
4
 V
A
C
COM
 
MOTOR CONTROL BOARD 
Figure 13 
Settable 
Switches 
Location 
Operating Mode  Switch 1  Switch 2  Switch 3  Switch 4 
B2 Operation 
ON 
OFF 
OFF 
OFF 
C2 Operation 
OFF 
OFF 
OFF 
OFF 
D1 Operation 
OFF 
ON 
OFF 
OFF 
E2 Operation 
ON 
ON 
OFF 
OFF 
TS Operation 
OFF 
OFF 
ON 
OFF 
T Operation 
ON 
OFF 
ON 
OFF 
SETTING THE SWITCH SELECTABLE OPERATING MODES
 
OPERATION & ADJUSTMENT INSTRUCTIONS 
17