Appendix C: MILLENNIUM II Transmitter Specifications 
  
Transmitter model 
Analog-Relay  
Analog 
Analog/HART 
Digital 
        Electrical
 
Power Consumption 
(with sensor attached) 
IR: <150 mA @ 24 VDC 
Solid State( H2S or Ammonia): 100mA @24VDC 
Voltage Range 
10.5 – 32 VDC     
10.5 – 32 VDC  
18 – 32 VDC  
10.5 – 32 VDC 
RFI, EMC, Immunity 
RFI: 150 to 170 MHz and 450 to 470 MHz, 5W FM radio at 1 meter away; EMC: IEC 61000-1-4 and IEC 
61000-4-3 Severity Level 2 
Display
 
Display 
OLED and Status LED’s (Separate status for Normal, Fault & Alarm) 
Environmental
 
Temperature 
Certified : -55°C to +85°C  
(Note: See sensor manuals for sensor certified temperatures). 
RH 
0 – 99% RH non-condensing 
Enclosure
 
Metallurgy 
Copper Free Aluminum (AL6061) or Stainless Steel (SS316) 
IP/NEMA 
IP67 / NEMA 4X 
Mounting
 
Mounting 
Surface Mount, Pipe Mount & other mounting options available. 
Outputs
 
Outputs 
(4) Mechanical Relays 
5A Form C contacts 
30VDC/250Vac   OR    
(4) Solid State Relays 
2.5A Form A contacts 
60VDC/VAC 
4 – 20 mA - into a 
maximum loop 
impedance of 800 Ohms 
@ 32VDC or 150 Ohms 
@ 10.5VDC. Isolated or 
non-isolated loop supply 
4 – 20 mA with HART 
communication protocol 
RS 485 Modbus RTU