Planar PS4650 User Manual

Page of 21
 
 
________________________________________________________________ 
V1.0 
2 / 21
 
Document 020-1156-00 Rev B
 
Introduction  
This document describes the hardware interface spec and software protocols of RS232 interface 
communication between Commercial Display and PC or other control unit with RS232 protocol. 
 
1. 
Protocol 1, with ID 
This set protocol allow user to assign the ID in the command to control the specify ID monitor 
2. 
Protocol 2, without ID 
The set protocol is best for single display control  
 
Both sets protocol contain three sections command: 
  Set-Function 
  Get-Function 
  Remote control pass-through mode 
※In below document, “PC” will represents all the control units that can sent or receive the RS232 
protocol command. 
Description 
2.1 
Hardware specification 
LCD communication port in the rear side  
(1) Connector type: DSUB 9 Pin Male  
(2) Pin Assignment  
 
 
 
        Male DSUB 9Pin 
        (outside view) 
 
 
 Pin  #   Signal   Remark  
1  
NC  
  
2  
RXD 
Input to LCD 
Monitor 
3  
TXD 
Output from LCD 
Monitor 
4  
NC  
  
5  
GND  
 
6  
NC  
  
7  
NC  
  
8  
NC  
  
9  
NC  
  
frame  
GND  
  
*Use of crossover (null modem) cable 
required for use with PC 
2.2 
Communication Setting  
 - Baud Rate Select: 
9600bps (fixed)  
 - Data bits:  
8bits (fixed)  
 - Parity:  
None (fixed)  
 - Stop Bits:  
1(fixed)  
 
2.3 Command Message Reference 
PC sends to Monitor command packet followed by “CR”. Every time PC sends control command to 
the Monitor, the Monitor shall response as follows: