Conduit seals
Section 3: Electrical installation
Daniel 3818 LNG Liquid Ultrasonic Meter Installation Manual
May 2012
3-9000-771 Rev A
3.4
Conduit seals
Daniel 3818 LNG Liquid Ultrasonic  Meters require conduit seals for installations in  hazardous 
environments. Adhere to safety instructions to protect personnel and equipment. 
HAZARDOUS VOLTAGE
Do not open the Transmitter Electronics Enclosure in a flammable gas area.  Disconnect 
power before servicing.
Do not disconnect equipment unless power has been removed or the area is known to be a 
non-hazardous. Failure to follow these instructions may result in serious injury or death.
EXPLOSION HAZARD
Substitution of components may impair the intrinsic safety and cause ignition of flammable 
or combustible atmospheres. Disconnect power before servicing.
Failure to remove power and use Daniel approved components  may cause serious injury.