Emerson 3-9000-771A User Manual

Page of 124
 48
Frequency/Digital outputs
Section 3: Electrical installation
Daniel 3818 LNG Liquid Ultrasonic Meter Installation Manual
May 2012
3-9000-771 Rev A
3.6.1
Frequency/Digital outputs
The meter has three user-configurable selections for configuring either a Frequency output or 
Digital output (FODO). 
FODO1 (four possible parameter configurations)
FODO2 (eight possible  parameter configurations)
FODO3 (eight possible  parameter configurations)
Frequency or Digital Outputs (FODO 1) source
FO1A, DO1A, FO1B, DO1B
Frequency output 1A is based on frequency content  (Actual - Uncorrected Flow Rate)
Frequency output 1B is based on frequency content and Frequency 1 B Phase
Digital output 1A is based on Digital output1A content (Frequency1A Validity and Flow 
Direction)
Frequency or Digital Outputs (FODO 2) source
FO1A, DO1A, FO1B, DO1B, FO2A, DO2A, FO2B, DO2B
Frequency output 1A is based on frequency content  (Actual - Uncorrected Flow Rate)
Frequency output 1B is based on frequency content and Frequency 1B Phase
Frequency output 2A is based on frequency content  (Actual - Uncorrected Flow Rate)
Frequency output 2B is based on frequency content and Frequency 2B Phase
Digital output 1A is based on Digital output1A content (Frequency 1A Validity and Flow 
Direction)
Digital output 2A is based on Digital output2A content (Frequency 1A Validity and Flow 
Direction)
Digital output 2A is based on Digital output 2A content (Frequency 2A Validity and Flow 
Direction)
Digital output 2B is based on Digital output 2B content (Frequency 2B Validity and Flow 
Direction)