B.  Mantel and Wall Projections
WARNING! Risk of Fire! Comply with all minimum clear-
ances to combustibles as specifi ed. Framing or fi nishing 
material closer than the minimums listed must be construct-
ed entirely of noncombustible materials (i.e., steel studs, 
concrete board, etc).
Clearance to combustible material under the insert is 1/4 
inch (6 mm). Clearance from top of fi replace opening for 
combustibles extending 12 inches max. is 12 inches.
•  Use leveling legs to raise insert minimum 1/4 inch (6 mm) 
above combustible material or outer wrap of factory built 
fi rebox.
Combustible facings must not extend behind the insert 
surround.  For non-combustible material specifi cations 
refer to section 1.E.
Figure 5.3 Mantel Clearances
12 IN. MIN.
12 IN. MAX.
EXISTING NON-COMBUSTIBLE FACING
Figure 5.2  Fireplace Opening - Deep Surround
C
D
SURROUND
APPLIANCE
1-1/2 IN.
B
D
A
D
APPLIANCE
SURROUND
MINIMUM FIREPLACE SIZE
Location
GRAND-I35
SUPREME-I30
Inches
Millimeters
Inches
Millimeters
A
D
Alternate Unit Width
33-3/16
843
29-1/16
738
B
D
Alternate Unit Depth
15-1/16
383
13-7/8
352
C
D
Alternate Unit Height
22-9/16
573
19-1/16
484
* Note: If exhaust collar on insert and fi replace damper do not line up, add 4 inches (102 mm) to minimum 
fi replace height for bends in vent pipe. 