Heat & Glo LifeStyle PIER-HV-IPI User Manual
Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/06
19
3
Installing the Fireplace
Step 1. Locating the Fireplace
The diagram below shows space and clearance require-
ments for locating a fireplace within a room.
ments for locating a fireplace within a room.
Figure 4A. Fireplace Dimensions and Locations
36"
GLASS
GLASS
GLASS
36"
GLASS
GLASS
36"
GLASS
36"
GLASS
GLASS
GLASS
36"
36"
36"
PIER-HV-IPI
TOP VIEW
RCOR-HV-IPI
TOP VIEW
LCOR-HV-IPI
TOP VIEW
ST-HV-IPI
TOP VIEW
Clearance Requirements
The top, back, and sides of the fireplace are defined by
stand-offs. The minimum clearance to a perpendicular wall
extending past the face of the fireplace is one inch (25 mm).
The metal ends of the fireplace may NOT be recessed into
combustible construction.
The top, back, and sides of the fireplace are defined by
stand-offs. The minimum clearance to a perpendicular wall
extending past the face of the fireplace is one inch (25 mm).
The metal ends of the fireplace may NOT be recessed into
combustible construction.
Note: Refer to Figure 4B for dimensions and appliance
locations if installing a Pier-HV unit with a Catalina shelf
and/or marble package.
locations if installing a Pier-HV unit with a Catalina shelf
and/or marble package.
Note: Refer to the Catalina installation instruction
included with kit for assembly and installation.
included with kit for assembly and installation.
Figure 4B.
50-1/2 in.
34-1/2 in.
7 in.
47-1/2 in.
45-1/4 in.
13/16 in.
Marble sizes (inches):
Header .................................. 26 x 8
Side headers .................. 45-1/2 x 8
Legs ................................ 33-1/2 x 7
Header .................................. 26 x 8
Side headers .................. 45-1/2 x 8
Legs ................................ 33-1/2 x 7
45 -1/4 in.
(1149mm)
(1149mm)
FINISHED
WALL
Fireplace Locations/Dimensions with
Catalina Shelf/Marble Package ONLY
Note: This location diagram MUST be followed when in-
stalling a Pier-HV with a Catalina shelf/marble package
since the fireplace is installed further from finished wall.
stalling a Pier-HV with a Catalina shelf/marble package
since the fireplace is installed further from finished wall.