Sony 900 User Manual

Page of 203
8
Chapter 8 Connectors and Cables
164
HDC-900/950/930 Series Product Information Manual
8-6-2
Cable Wiring
CCA-5 Cable 
8-6-3
Connection Connector
Connections made with the connector panels during 
installation or service should be made with the 
connectors/complete cable assemblies specified in 
the following list, or equivalent parts.
Connector name 
Connection connector/cable
REMOTE AUX (8-pin)  Plug 8-pin, Male (Sony part 
number: 1-766-848-11)
REMOTE CCU/CNU 
(8-pin) or
CCA-5 cable assembly 
(Option)
CCA-5-3 (3 m)/CCA-5-10 (10 
m)
I/O PORT (50-pin) 
Plug, D-SUB 50-pin, Male 
(Sony part number: 1-566-
358-11)
or
JAE DDU-50PF-F0 or 
equivalent
8-7.
MSU-750, Master Setup Unit
8-7-1
Connector Panel
a
POWER switch
Turns the power on and off of this unit.
b
AC IN (AC power input) connector
Connect to an AC power source using an optional AC 
power cord. The power cord can be fixed to this unit 
using an optional plug retainer.
c
AUX REMOTE (auxiliary remote) connector (8-
pin)
d
CCU/CNU REMOTE (camera control unit/camera 
command network unit remote) connector (8-
pin)
Connect to the RCP/CNU connector of the CCU or the 
MSU connector of the CNU.
Black
White
White
Brown
White
Red
Red
Brown
Brown
Orange
1
2
3
4
8
5
6
7
1
2
3
4
8
5
6
7
8-pin connector (Male)
(Wiring side)
8-pin connector (Male)
(Wiring side)
POWER
I
O
AUX
CCU/CNU
REMOTE
-
AC IN
1
POWER switch
2
AC IN connector
4
CCU/CNU REMOTE connector
3
AUX REMOTE connector