INSTALLATION CLEARANCES
Minimum clearances to combustible construc-
tion are:
•  Top, Back and Sides of Recessed 
  Cabinet  . . . . . . . . . . . . . . . . . . . . .0" Min.
•  Drywall to Sides of Front Face  . . .0" Min.
•  Framing at Nailing Flanges . . . . . .0" Min.
•  Ceiling to Opening . . . . . . . . . . . .36" Min.
•  Floor  . . . . . . . . . . . . . . . . . . . . . . .0" Min.
•  Front  . . . . . . . . . . . . . . . . . . . . . .36" Min.
•  Perpendicular Side Wall  . . . . . . .10" Min.
Mantel Clearances
For mantel clearances see Figures 3 and 4.
CABINET MANTEL INSTALLATION
This fireplace may be installed using a cabi-
net  mantel  accessory  against  any  wall  with 
an  available  120  volt  grounded  outlet.  The 
cabinet  mantel  accessory  includes  both  a 
base and a trim kit.
INSTALLATION
Continued
Facing Material May 
Be Noncombustible 
Wall Treatments or 
Combustible Wood
Combustible Wood
Mantels and Trims
May Extend Above
Profile Shown when
Maintained within 30°
Parameter Shown
Framed 
Material
Top of Cabinet
Note: All Mantel Clearances
are Measured from Top of
Fireplace Opening
30°
16 
5
/
8
"
Ref.
5
/
8
" Ref.
12" Ref.
13 
3
/
4
"
1
/
2
"
1
/
2
"
3
/
4
"
10 
1
/
2
" Min.
10 
1
/
2
"
Figure 3 - Mantel Clearances
Top View of Fireplace
Safe Zone
5"
3"
30°
3
/
4
" Max.
Minimum 10" from
Perpendicular Side Wall
Edge of Firebox 
Opening
Combustible 
MaterialMust 
Not Overlap 
Front Face
Figure 4 - Mantel Side Clearances
Figure 5 - Installing Flush Cabinet Mantel
Cabinet
Mantel
Perimeter 
Trim 
Accessory
Electric
 Outlet
Power 
Cord
IMPORTANT: To install perimeter trim kit, you 
must install shoulder screws before installing 
fireplace into cabinet mantel. See instructions 
included with trim kit. When installing a man-
tel accessory, you must follow all clearance 
instructions  (see  Installation  Clearances
column 1).
1.  Assemble cabinet mantel accessory and 
trim kit by following assembly instructions 
included with each kit.
2.  Place hearth base close to wall at desired 
location. Leave enough room to get be-
hind unit and attach mantel to base once 
fireplace  and  mantel  has  been  placed. 
When possible, location should be within 
3"  of  power  outlet  so  mantel  will  cover 
outlet  with  installed  (see  Figure  5  and 
Figure 6, page 5).
3.  Plug power cord into outlet.
 
Note: Power cord comes preattached to 
right side of cabinet. If it is necessary to 
relocate cord to left side you must remove 
power cord assembly (see Figure 7). Fol-
low instructions to relocate junction box 
(see  Electrical  Installation,  on  page  6). 
Power  cord  must  be  properly  mounted 
and reconnected at junction box.
4.  Slide assembled mantel over fireplace un-
til nailing flanges are centered into opening 