Vanguard VE32L User Manual

Page of 28
www.desatech.com
115121-01B
15
MAINTENANCE
  WARNING:  Disconnect 
power  before  attempting  any 
maintenance or cleaning to re-
duce  the  risk  of  fire,  electrical 
shock or personal injury.
  WARNING:  Any  electrical 
repairs  or  rewiring  of  this  unit 
should  be  carried  out  by  a 
licensed  electrician  in  accor-
dance  with  national  and  local 
codes.
  WARNING:  Do  not  exceed 
60 watts per bulb when replac-
ing  bulbs.  Use  of  higher-rated 
bulbs may result in a fire, caus-
ing property damage, personal 
injury, or loss of life.
REPLACING LIGHT BULBS
There are (3) colored lamps rated at 120V, 
60 Watts, for use in a medium sized socket. 
These  bulbs  are  located  under  the  log  bed 
and can be replaced as follows:
1.  If  you  are  unsure  which  bulb  needs 
replacement,  defective  bulbs  may  be 
visually located as any of 3 bulbs colored 
- Red, Yellow and Orange starting from 
the left (see Figure 12, page 7). Defective 
bulbs can be replaced individually or for 
convenience you may want to replace all 
bulbs at the same time; even if only one 
is defective.
2.  Disconnect power to unit at main breaker 
or fuse panel.
3.  Lift log bed off hearth base to gain access 
to lamp fixtures. Log bed is attached with 
contact magnets only.
4.  Remove  each  defective  bulb  from  its 
socket and replace with appropriate color 
and size bulb.
Note: Be careful not to tear or damage reflec-
tive  ribbons.  If  they  have  come  loose,  they 
can be easily reattached or replaced at the 
support  brackets.  See  Replacing  Reflective 
Ribbons
, page 21.
5.  Return power to circuit and turn main power 
switch and lamp power on to check opera-
tion of bulbs before replacing log set.
6.  If all bulbs are working properly, replace 
the  log  bed  over  the  center  opening  in 
between rear screen and front grate.
 CAUTION: Make sure power 
is turned off at supply prior to 
disassembling this unit.
MAINTAINING MOTORS
Motors  used  on  fan  and  heater  assembly 
are  permanently  lubricated  and  do  not 
require  lubrication. Annual  cleaning  and/or 
vacuuming  around  heater  and  fan  unit  is 
recommended.
REMOvING/REPLACING CONTROL 
DOOR
The upper control door may be removed for 
service or replacement when necessary:
1.  Open upper control door (see Figure 13, 
page 7).
2.  Remove 4 Phillips screws from deflector 
shield. Angle deflector shield out of open-
ing (see Figure 29).
3.  Remove  4  Phillips  screws  from  magnet 
assemblies.
4.  Lift  up  on  inner  control  door  and  push 
in  each  end  until  pivot  pins  are  free  of 
notches located on each side of access 
opening (see Figure 29).
Figure 29 - Removing/Replacing Control 
Door
Deflector 
Shield
Control 
Door
Magnet 
Assembly
Push 
Door Up 
and 
Back 
Angle 
Door and 
Slide 
Out of 
Housing.