LENNOX HEARTH PRODUCTS  •  MERIT
® 
 SERIES DIRECT-VENT GAS FIREPLACES  •  MODELS MLDVT-30/35/40/45  •  INSTALLATION INSTRUCTIONS
       WARNING 
Improper  installation,  adjust-
ment,  alteration,  service  or 
maintenance  can  cause  injury 
or  property  damage.    Refer  to 
this manual.  For assistance or 
additional  information  consult 
a  qualified  installer,  service 
agency or the gas supplier.
       WARNING 
Failure  to  comply  with  these 
installation instructions will result 
in  an  improperly  installed  and 
operating appliance, voiding its 
warranty.  Any change to this appli-
ance and/or its operating controls 
is dangerous.
       WARNING 
Clothing  or  other  flammable 
material  should  not  be  placed 
on or near the appliance.
       AVERTISSEMENT 
On  ne  devrait  pas  placer  de 
vêtements  ni  d’autres  matières 
inflammables sur l’appareil ni à 
proximité.
       WARNING 
Any  safety  screen  or  guard 
removed for servicing the appli-
ance must be replaced prior to 
operating the appliance.
       AVERTISSEMENT 
Tout écran ou protecteur retiré 
pour  permettre  l’entretien  de 
l’appareil  doit  être  remis  en 
place avant de mettre l’appareil 
en marche.
Note: Installation and repair should be done 
by a qualified service person. The appliance 
should be inspected before use and at least 
annually by a professional service person. 
More frequent cleaning may be required due 
to  excessive  lint  from  carpeting,  bedding 
material, etcetera. It is imperative that control 
compartments,  burners  and  circulating  air 
passageways of the appliance be kept clean.
Remarque  :  L’installation  et  la  réparation 
devrait être confiées à un technicien qualifié. 
L’appareil devrait faire l’objet d’une inspec-
tion  par  un  technicien  professionnel  avant 
d’être utilisé et au moins une fois l’an par la 
suite. Des nettoyages plus fréquents peuvent 
être  nécessaires  si  les  tapis,  la  literie,  et 
cetera produisent une quantité importante de 
pous-sière. Il est essentiel que les comparti-
ments abritant les commandes, les brûleurs et 
les conduits de circulation d’air de l’appareil 
soient tenus propres.
Do  not  use  these  appliances  if  any  part 
has been under water.  Immediately call a 
qualified, professional service technician 
to  inspect  the  appliance  and  to  replace 
any  parts  of  the  control  system  and  any 
gas control which have been under water.
Ne pas utiliser cet appareil s’il a été plongé, 
même  partiellement,  dans  l’eau.  Ap-
peler un technicien qualifié pour inspecter 
l’appareil  et  remplacer  toute  partie  du 
système de commande et toute commande 
qui a été plongée dans l’eau.
Only trim kit(s) supplied by the manufacturer 
shall be used in the installation of this ap-
pliance.
Seules  les  trousses  de  garniture  fournies 
par le fabricant doivent être utilisées pour 
l’installation de cet appareil.
These appliances comply with National Safety 
Standards  and  are  tested  and  listed  by  ETL/
Intertek  (Report  No.  100326540PRT-001)  to 
ANSI Z21.88 (in Canada, CSA-2.33), and CAN/
CGA-2.17-M91  in  both  USA  and  Canada,  as 
vented gas fireplace heaters.
Both  millivolt  and  electronic  versions  of 
these  appliances are listed by ETL/Intertek 
for installation in bedrooms and Manufac-
tured Homes. 
Misc. Codes/Standards
The Installation must conform to local codes or, 
in the absence of local codes, with the National 
Fuel Gas Code, ANSI Z223.1/NFPA 54 - latest 
edition (In Canada, the current CAN/CSA-B149.1 
installation code).
The appliance, when installed, must be electri-
cally grounded and wired in accordance with 
local codes or, in the absence of local codes, 
with the National Electrical Code, ANSI/NFPA 
70 - latest edition, or the Canadian Electrical 
Code, CSA C22.1 - latest edition.
Provide adequate clearances around air open-
ings and adequate accessibility clearance for 
service and proper operation. Never obstruct 
the front or back openings of the appliance.
These appliances are designed to operate on 
natural or propane gas only. The use of other 
fuels  or  combination  of  fuels  will  degrade 
the performance of this system and may be 
dangerous.
These fireplaces are designed as supplemental 
heaters.  Therefore,  it  is  advisable  to  have  an 
alternate  primary  heat  source  when  installed 
in a dwelling.
These appliances must not be connected to a 
chimney  or  flue  serving  a  separate  solid  fuel 
burning appliance.
Millivolt Models - The millivolt appliances are 
manually controlled and feature a spark igniter 
(piezo) that allows the appliance's pilot gas to 
be lit without the use of matches or batteries.  
This system provides continued service in the 
event of a power outage.
Millivolt models come standard with a manually-
modulated gas valve; flame appearance and heat 
output can be controlled at the gas valve. The BTU 
Input for these appliances is shown in Table 1.
Electronic  Models  -  These  electronic  appli-
ances are manually controlled and feature an 
electronic  intermittent  pilot  ignition  system.  
External electrical power is required to operate 
these units.
These electronic models come standard with a 
manually-modulated gas valve; flame appear-
ance and heat output can be controlled at the 
gas valve. The BTU Input for these appliances 
is shown in Table 1.
 Input (BTU/HR) Manually Modulated 
Gas Valves (all models)
Models
Input Rate (BTU / HR)
Nat. Gas
Prop. Gas
MLDVT-30
  
13,500 high
10,500 low
12,500 high
9,000 low
MLDVT-35
 
16,000 high
12,500 low
15,000 high
11,500 low
MLDVT-40
20,000 high
15,500 low
20,000 high
15,800 low
MLDVT-45
23,000 high
17,500 low
22,000 high
17,000 low
Table 1