SPECIFICATIONS:  Model L30 BF-2
PAGE 22
Approx. Sq. Ft.
Heating Capacity
∼∼∼∼
1500 sq. ft.
Flue Size
4” - Top Vent
Height Overall
29”
Height to Flue
Outlet
30 3/8”
Width
29 7/8”
Depth 16 
1/8”
Fuel
Natural Gas (standard)
(or) LP Gas (convertible).
Gas inlet 3/8” NPT-Male / Flex Line
(or) remove flex, 3/8” NPT–Female Flare.
Performance
Variable Flame Control.
Features
High Efficiency Heat Exchanger.
Natural Convection & Radiant Heat.
Standing Pilot / Operates During Power
Outages. Remote Control & Wall
Thermostat Capable.
Technical 
Honeywell Combination Gas Control
Features
Valve, Millivolt - VS8520E. Safety Shut
Down Sensor (Spill Switch).
Pan Burner with Tuned Ports.
Radiant & Fan Assisted Convection
Heat.
Safety Test
Tested and certified by CSA to ANSI
standards. Z21.88 – (1998) 
••••
 CSA 2.33 -
(1998). Vented Gas Fireplace Heater .
Heat Input
25,000 to 37,000 BTU’s (Nat. Gas)
28,000 to 35,000 BTU’s (Propane)
Ship Weight
200 lb.’s
Dimensions shown are approximations only (+ / - ¼”)
Top View
Side View
~
 Square feet heating capacities are approximations only.
They will vary depending upon level of insulation, climate,
house design, ceiling height, ambient outside tempera-
tures and how stove is operated.
SPECIFICATIONS
GAS TYPE
NATURAL
GAS
PROPANE
(LP)
CLEARANCES TO COMBUSTIBLES
Orifice Size
#31 -.120
#50-.070”
Back Wall Min.
2 In. / 51 mm
Minimum Supply Pressure
4.5” WC
10.5” WC
Side Wall Min.
12 In. / 305 mm
Maximum Supply Pressure
10.5” WC
13.0” WC
Corner (45
°°°°
 angle)s
HIGH SETTING
   stove corner to wall, min.
4 In. / 102 mm
    Manifold Pressure
3.5” WC
10.0” WC
Ceiling Height Minimum
65 In. / 1651 mm
Input BTU / HR
37,000
35,000
Alcove Min. Height
65 In. / 1651 mm
LOW SETTING
Alcove Min. width
54 In. / 1372 mm
Mainfold Pressure
1.8” WC
6.6” WC
Alcove -  Max. Depth into
Input BTU / HR
25,000
28,000
   stove face to alcove opening
24 In. / 610 mm
 Altitude - U.S.A. 0-4,500 Ft. (0-1372M) No derating
 Altitude - Canada 0-4,500 Ft. (0-1372M) No derating
For installation higher than altitudes shown above, reorifice per Gas
Codes.
* With the orifice, manifold pressure and input
ratings shown above.
This Appliance is equipped at the factory for the use with Natural Gas or Propane (LP). Appliances using propane must
be field conversed using the LP Conversion Kit supplied with appliance.