Regency P40-NG1 User Manual
Regency
®
P40-1 Direct Vent Gas Fireplace
21
INST
ALLA
TION
INSTALLATION
• Vent must be supported at offsets.
• Firestops are required at each fl oor level and
• Firestops are required at each fl oor level and
whenever passing through a wall.
• Maintain clearances to combustibles as listed
in the "Clearances" section.
•
Refer to "Vent Restrictor Position" section for
details on how to change the vent restrictor
to Set 1 or Set 2 if required.
details on how to change the vent restrictor
to Set 1 or Set 2 if required.
Note: Must use optional fl ue adapter when using
Rigid Pipe (Part # 770-994).
VENTING ARRANGEMENTS
ALLOWABLE VERTICAL TERMINATIONS
Maximum:
40
ft.
(12.2m)
Minimum
8
’9”
(2.6m)
Max. 10’ (3m)(centerline to centerline)
Minimum 12” (305mm)
Maximum:
28
ft.
(8.5m)
0
2
4
6
40
8
10
12
14
16
18
20
22
24
26
28
30
V
ertical
Height
(Feet)
32
34
36
38
6
8
2
0
4
10
12
12
16
18
14
20
26
28
22
24
30
Vent Restrictor on Set 1
Vent Restrictor on Set 2
Vent Restrictor
Factory Set
The shaded area in the diagram shows all allowable
combinations of straight vertical and offset to vertical
terminations, using two 90
combinations of straight vertical and offset to vertical
terminations, using two 90
o
elbows, with Rigid Pipe
Venting Systems for Propane and Natural Gas.
Two 45
Two 45
o
elbows equal to one 90
o
elbow. Maximum
of four 45
o
elbows allowed.