Regency P48-LP User Manual

Page of 48
Regency P48 Zero Clearance Direct Vent Gas Fireplace
18
INSTALLATION
Vent must be supported at offsets.
Firestops are required at each floor level and whenever passing through a wall.
Maintain clearances to combustibles.
Note: Must use optional flue adapter when using Simpson Dura-Vent pipe (Part # 510-994).
VENTING ARRANGEMENTS - VERTICAL  TERMINATIONS
SIMPSON DURA-VENT DIRECT VENT GS SYSTEM
(Propane & Natural Gas)
The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations , using two 90
o
 elbows,
with  Simpson Dura-Vent Direct Vent GS vent systems for Propane and Natural Gas.