Regency P40-NG User Manual

Page of 48
Regency
®
 P40 Direct Vent Gas Fireplace
35
OPERA
TION
OPERATING INSTRUCTIONS
SUMMARY OF 
CONTROLS 
For the Manual Control Box, located on 
right hand side of the bottom louver.
On/Off Button
If the unit  is off, pressing and releasing this 
button once will switch the unit on. The unit will 
be on high for 20 seconds and then resume to 
its last settings.
If the unit is on, pressing and releasing this 
button once will switch the unit off.
Flame:
There are seven fl ame settings that can be 
adjusted by pressing and releasing the plus (+) 
and  minus (-) FLAME button.
Increase: If the unit is on, pressing and releasing 
the fl ame plus (+) button once will increase the 
fl ame height to the next available high setting.
Decrease: If the unit is  on, pressing and releasing 
the fl ame minus (-) button once will decrease the 
fl ame height to the next available low setting.
Fan:
There are three fan speeds that can be adjusted 
by pressing and releasing the plus (+) and  minus 
(-) FAN button.
Pressing and releasing the plus (+) FAN button 
will change the fan speed as follows:
OFF -> LOW -> MEDIUM -> HIGH -> OFF
Pressing and releasing the minus (-) FAN button 
will be the reverse of the above.
OPERATION DURING 
POWER OUTAGE
Important:
If the unit is not used for a prolonged period of 
time, we recommend turning the 3-way switch 
on the manual control panel to "Off".  Also see 
"Lighting Plate Instructions" for details on how to 
turn off the pilot.
NOTE:   The fan will not operate during a  
 power 
outage. 
Rear Burner  
Switch
3-way Switch
Manual Control Panel
When in "Remote" position;
In the event of a power failure, if the 3-way switch 
is in the "Remote" position, the unit cannot be 
operated with the Remote Control until after 
power is restored.
To operate unit during a power failure;
NOTE: Both burners when on will operate at the 
lowest fl ame setting. The BTU's for NG 
will be 13,000 and 12,000 for LP.
Front Burner Operation:
1)  Open the bottom louver to gain access to 
the Manual Control Panel.
2)  To turn on the front burner, change the 3-way 
switch to "Manual" position.
Rear Burner Operation:
1)  Open the bottom louver to gain access to 
the Manual Control Panel.
2)  To turn on the rear burner, change the Rear 
Burner Switch to the "On" position. Changing 
the switch to the "Off" postion will turn the 
rear burner off.
 
Note: The rear burner will only operate if the 
front burner is on.
Manual Control Box
Fan Control 
Buttons
Unit
On/Off 
Button
Flame 
Control 
Buttons
FIREWIZARD
TM
 REMOTE 
CONTROL FUNCTIONS 
 
The FireWizard
TM
 Remote Control was de-
veloped to provide a user-friendly system to 
operate your appliance. The operating range 
is approximately 10 metres (32 feet) from the 
fi replace.
See FireWizard Remote Control Manual for 
complete details on operation functions and 
instructions.
When in "Manual" position;
In the event of a power failure, if the 3-way switch 
is in the "Manual" position the front buner will 
remain on at the lowest setting and will remain 
on when power resumes. If the rear burner is 
not in use, to operate see "Rear Burner Opera-
tion" above.
Both burners when on will operate at the lowest 
fl ame setting. The BTU's for NG will be 13,000 
and 12,000 for LP.
When power resumes the unit will remain on at 
the lowest setting until reset using the remote 
control.
NOTE: When power is restored, reset the 
3-way switch on the Manual Control 
Panel to the "Remote" position to be 
able to use the FireWizard
TM
 Remote 
Control.