MAINTENANCE
VALVE REPLACEMENT
1)  Shut off the main gas supply and unplug 
the power to the ECS system.
2)  Remove the main gas line pipe from the
 gas 
valve.
3)  Remove logs and brick panels if installed.
4)  Remove the fender by undoing the 2 screws, 
one on the left and right side.
5)  Remove the front air box by undoing the 3 
screws.
Fender
6)  Remove the front burner by removing the 2 
screws and swing the burner to the left and 
slide out.
Front Air Box
7)  Carefully remove the base brick panel.
8)  Remove the 2 screws on the back burner.
9)  Slide burner to the right and lift out.
10)  Remove back air box by removing 2 screws, 
one on the left and one on the right side and 
pull out.
Back Burner
14) Remove all 22 valve tray screws and care-
fully lift out the valve tray.
Back 
Burner
MAINTENANCE
11) Unplug the 3 black wires at the DC 
Sparker.
12) Unplug the 5 wires at the valve (2 grey, 2 
red and 1 black.
13) Reach in and grab the black and red wires 
leading to the solenoid valve and disconnect 
them.