VENTING ARRANGEMENTS 
ALLOWABLE VERTICAL TERMINATIONS
•   Vent must be supported at offsets.
•    Firestops are required at each fl oor level and 
whenever passing through a wall.
•    Maintain clearances to combustibles as listed 
in the "Clearances" section.
• 
Refer to "Vent Restrictor Position" section for 
details on how to change the vent restrictor 
to Set 1, Set 2 or Set 3 if required.
Note: Must use optional fl ue adapter when using 
Rigid Pipe (Part # 770-994).
INSTALLATION
The shaded area in the diagram shows all allowable 
combinations of straight vertical and offset to vertical 
terminations, using two 90
o
 elbows,  with Rigid Pipe 
Venting Systems for Propane and Natural Gas.  
Two  45
o  
elbows equal to one 90
o
 elbow.  Maximum 
of four 45
o
 elbows allowed.