Regency P48-1 User Manual

Page of 48
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace
16
INSTALLATION
Horizontal Venting with Three (3) 90
o
 Elbows
Option     V
  H          V + V1
 H + H1
     A)
2' Min.
1' Max.
3' Min.
 4' Max.
     B)
3' Min.
2' Max.
4' Min.
 5' Max.
     C)
4' Min.
3' Max.
6' Min.
 6' Max.
     D)
5' Min.
4' Max.
8' Min.
 7' Max.
     E)
6' Min.
5 Max.
10' Min.  8' Max.
     F)
7' Min.
6' Max.
12'  Min.  9' Max.
Vertical Venting with Two (2) 90
o
 Elbows
Option V
    H
V + V1
     A)
1' Min.
4' Max.
2' Min.
     B)
2' Min.
5' Max.
3' Min.
     C)
3' Min.
6' Max.
4' Min.
     D)
4' Min.
7' Max.
5' Min.
     E)
5' Min.
8' Max.
6' Min.
Vertical Venting with Two (2) 90
o
 Elbows
With these options, max. total
pipe length is 30 feet with min.
of 6 feet total vertical and max.
8 feet total horizontal.
Please note min. 1 foot
between 90
o
 elbows is re-
quired.
Option  H + H1        V
     A)
 2' Max.    2' Min.
     B)
 3' Max.    3' Min.
     C)
 4' Max.    4' Min.
     D)
 5' Max.    5' Min.
     E)
 6' Max.    6' Min.
With these options, max. total
pipe length is 30 feet with min.
of 6 feet total vertical and
max. 6 feet total horizontal.
Please note min. 1 foot
between 90
o
 elbows is re-
quired.
One 90
o
 elbow = Two 45
o
 elbows.
One 90
o
 elbow = Two 45
o
 elbows.
One 90
o
 elbow = Two 45
o
 elbows.
For additional vertical vent-
ing with 2 x 90
o
 elbows,
refer to page 18.
With these options,
max. total pipe length
is 30 feet with min. of
12 feet total vertical
and max. 9 feet total
horizontal.
Please note min. 1
foot between 90
o
elbows is required.