Regency P33-NG4 User Manual

Page of 52
Regency
®
 P33-4 Zero Clearance Direct Vent Gas Fireplace
12
IMPORTANT
If using any Cabinet Mantels with Part # 
510956, 510958, 510962, 510964 and 
510834 the wall thimble must be secured fi rst 
and venting must be attached to unit before 
sliding into fi nal position.
Also Rigid Vent venting cannot be used with 
any of the mantels noted above. See Price 
Pages for alternative options.
Wherever necessary due to 
external location of cap, the 
AstroCap can be replaced with 
the FPI Riser Vent Termination 
Cap or the Dura-Vent Snorkel 
Termination Cap.
INSTALLATION
REGENCY
®
 DIRECT VENT FLEX SYSTEM 
Horizontal Terminations Only
This venting system, in combination with the P33-4 Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by Warnock 
Hersey. The location of the termination cap must conform to the requirements in the "Exterior Vent Terminal Locations" Section .
Regency
®
 Direct Vent Flex Termination Kit (Part # 946-513) includes all the parts needed to install the P33-4 with a maximum run of 2 
feet. If installing the P33 with a continuous vent length of more than 2 ft (.6m) to a maximum of 10 ft. (3.0m) use Kit # 946-515 (4 ft) or 946-516 
(10 ft) or see "Rigid Pipe Venting Systems" Section for alternate venting arrangements.
1)  6-7/8" dia. fl exible liner (2 ft. length)
2)  4" dia. fl exible liner (2 ft. length)
3) spring 
spacers 
(3)
4) thimble 
(2)
5)  AstroCap termination cap (1)
6) screws 
(12)
7)  tube of Mill Pac (1)
8) plated 
screws 
(8)
9)  screws #8 x 1-1/2" drill point, 
 stainless 
steel 
(4)
6-7/8"
(173mm)
dia. Flue pipe
4" (102mm)
dia. flue pipe
Wall Thimble (2 pc)
(required in
Canada only)
Termination Cap
(Part# 946-523/P)
AstroCap
TM
spring
spacer
See Figure 1 below 
for Alternate Caps.
Notes: 
1)  Liner sections should be continuous 
without any joints or seams.
2)  Only Flex pipe purchased from Regency
®
 
may be used for Flex installations.
MINIMUM 
FLEX KIT CENTER-LINE
MINIMUM
RIGID PIPE CENTER-LINE
Alternate 
Horizontal 
Termination 
Caps
Figure 1