5
INSTALLATION
INSTALLATION
CHECKLIST
1) Locate appliance
a) Room location, page 8.
b) Clearances  to  Combustibles,
page 9.
c) Mantle Clearances, page 9.
d) Framing & Finishing Requirements,
page 10.
e) Flueing Requirements, pages 11-19.
2) Assemble Top Standoffs,  page (NOTE:
page 11 must be done before installing unit
into  fireplace.)
3) Install flue, pages 19-21.
4) Make gas connections. Test the pilot. Must
be as per diagram. Page 22.
5) Install  log  set  where  indicated  on
page 24-25.
6) Glass Door Removal (page 26), Louvers
or  Grills  (page  26),  and  Finishing  Trim
(page  26).
7) Install optional Wall Switch, Remote Con-
trol, or Wall Thermostat, page 27.
8) Final check.
Before leaving this unit with the customer, the
installer must ensure that the appliance is firing
correctly and operation fully explained to cus-
tomer.
This includes:
1) Clocking the appliance to ensure the cor-
rect firing rate (rate noted on label 40,000
Btu/h  NG,  and  39,000  Btu/h  LPG)  after
burning appliance for 15 minutes.
2) If  required,  adjusting  the  primary  air  to
ensure  that  the  flame  does  not  carbon.
First allow the unit to burn for 15-20 min.
to stabilize.
CAUTION:  Any  alteration  to  the  product
that  causes  sooting  or  carboning  that
results  in  damage  is  not  the  responsi-
bility  of  the  manufacturer.
IMPORTANT:
SAVE  THESE
INSTRUCTIONS
The Regency P121/P121LC/P121RC/P131-NG
or  P121/P121LC/P121RC/P131-LPG 
 
Room
Sealed Gas Fireplace must be installed in ac-
cordance AG601 and NZS 5261 and with these
instructions.
 
Carefully read all the instructions
in this manual first. Consult the "authority having
jurisdiction" to determine the need for a permit
prior to starting the installation. It is the respon-
sibility of the installer to ensure this fireplace is
installed  in  compliance  with  manufacturer's
instructions and all applicable codes.
BEFORE  YOU  START
Safe installation and operation of this appliance
requires  common  sense,  however,  we  are
required to
 
make you aware of the following:
GENERAL  SAFETY
INFORMATION
1) The appliance shall be installed in accord-
ance  with  the  manufacturer's  installation
instructions,  local  gas  fitting  regulations,
municipal building codes, water supply reg-
ulations, electrical wiring regulations, with
AS5601-2004 (AGA gas installation code)
NZS 5261 (New Zealand)
2) See  general  construction  and  assembly
instructions. The appliance and flue should
be  enclosed.
3) This appliance must be connected to the
specified  flue  and  termination  cap  to  the
outside of the building envelope. Never flue
to another room or inside a building. Make
sure  that  the  flue  is  fitted  as  per  Flueing
instructions.
4) Inspect  the  flueing  system  annually  for
blockage and any signs of deterioration.
5) Flueing terminals shall not be recessed into
a wall or siding.
6) Any  safety  glass  removed  for  servicing
must  be  replaced  prior  to  operating  the
appliance.
7) To prevent injury, do not allow anyone who
is unfamiliar with the operation to use the
fireplace.
8) Wear  gloves  and  safety  glasses  for  pro-
tection while doing required maintenance.
9) Be  aware  of  electrical  wiring  locations  in
walls  and  ceilings  when  cutting  holes  for
termination.
10) Under no circumstances should this appli-
ance  be  modified.  Parts  that  have  to  be
removed for servicing should be replaced
prior to operating this appliance.
11) Installation and any repairs to this appliance
should  be  done  by  a  authorized  service
person. A authorized service person should
be called to inspect this appliance annually.
Make it a practice to have all of your gas
appliances checked annually.
12) Do not slam shut or strike the glass door.
13) Under no circumstances should any solid
fuels (wood, paper, cardboard, coal, etc.)
be used in this appliance.
INSTALLATION AND REPAIR SHOULD
BE DONE BY A AUTHORIZED SERVICE
PERSON. THE APPLIANCE SHOULD BE
INSPECTED  BEFORE  USE  AND  AT
LEAST ANNUALLY BY A AUTHORIZED
SERVICE PERSON. MORE FREQUENT
CLEANING MAY BE REQUIRED DUE TO
EXCESSIVE LINT FROM CARPETING,
BEDDING MATERIAL, ETC. IT IS IMPER-
ATIVE  THAT  CONTROL  COMPART-
MENTS, BURNERS AND CIRCULATING
AIR PASSAGEWAYS OF THE APPLI-
ANCE BE KEPT CLEAN.
DUE TO HIGH TEMPERATURES, THE
APPLIANCE SHOULD BE LOCATED OUT
OF TRAFFIC AND AWAY FROM FURNI-
TURE AND DRAPERIES.
WARNING: FAILURE TO INSTALL THIS
APPLIANCE CORRECTLY WILL VOID
YOUR WARRANTY AND MAY CAUSE A
SERIOUS HOUSE FIRE.
CLOTHING OR OTHER FLAMMABLE MA-
TERIAL SHOULD NOT BE PLACED ON
OR NEAR THE APPLIANCE.
CHILDREN AND ADULTS SHOULD BE
ALERTED TO THE HAZARDS OF HIGH
SURFACE TEMPERATURES, ESPECIAL-
LY  THE  FIREPLACE  GLASS,  AND
SHOULD STAY AWAY TO AVOID BURNS
OR CLOTHING IGNITION.
YOUNG CHILDREN SHOULD BE
CAREFULLY  SUPERVISED WHEN THEY
ARE IN THE SAME ROOM AS THE AP-
PLIANCE.
Emissions from burning  wood or gas could
contain  chemicals  known  to  the  State  of
California to  cause cancer, birth defects or
other  reproductive  harm.
Note: These units are
non-load bearing.
14) The appliance area must be kept clear and
free of combustible materials, (gases and
other flammable vapours and liquids).