Regency P36-NG4 User Manual

Page of 8
16
2
2
0
0
12
12
6
6
18
4
40-1/2"
(1029mm)
Minimum
Height
Requirement
4
14
8
8
10
10
14
16
18
20
V
ertical
Height
(Feet)
Horizontal (Feet)
P36D ONLY
Please refer to Page 11 (Exterior Vent Terminations) 
for additional guidelines on vent locations.
P36 - P36D Gas Fireplace
Venting Arrangements - Horizontal 
Terminations
This diagram shows all allowable combinations of vertical runs with 
horizontal terminations, using one 90º elbow (two 45º
 
elbows equal 
one 90º elbow).
The lightly shaded area, 
6
8
2
0
4
10
0
2
4
6
40
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
12
, in the diagram shows allowable 
combinations when installing a P36
The darker shaded area, 
6
8
2
0
4
10
0
2
4
6
40
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
12
, in the diagram shows additional allowable 
combinations when installing a P36D.
Note:  Must use optional fl ue adapter (Part # 510-994) when using 
Rigid Pipe.
•  
Maintain clearances to combustibles.
•  
Horizontal vent must be supported every 3 feet.
•  
Firestops are required at each fl oor level and whenever passing 
through a wall.
A vent guard may be required as per  local codes, refer to page 11 for 
“Exterior Vent Termination Locations”.
Note:  FPI Direct Vent System (Flex) is only approved for horizontal 
terminations.
40
June 2007 Regency Product Specifi cations Book
Gas Fir
eplaces
Gas Fireplaces