LOCATING  YOUR
GAS  FIREPLACE
1) When selecting a location for your stove,
ensure  that  the  clearances  are  met  as
outlined on page 9.
2) Provide  adequate  clearances  for  servic-
ing.
3) The appliance must be installed on a flat,
solid, continuous surface (e.g. wood, met-
al,  concrete).  This  may  be  the  floor,  or
raised up on a platform to enhance its visual
impact. If the appliance is going to be in-
stalled on carpeting, combustible linoleum
tile or other combustible material other than
wood  flooring,  the  appliance  must  be  in-
stalled on a metal or wood panel extending
the full width and depth of the appliance.
4) The  Room  Sealed  Gas  Fireplace  can  be
installed  as  follows:
Model # Position
A)
P121: See Thru
B)
P131: Pier
C)
P121LC: Left Corner
D)
P121RC: Right Corner
5) This appliance is Listed for bedroom  instal-
lations  when  used  with  a  Listed  Millivolt
Thermostat. Some areas may have further
requirements,  check  local  codes  before
installation.
6) The  P121/P121LC/P121RC/P131  Room
Sealed  Gas  Fireplace  is  approved  for  al-
cove  installations,  which  meet  the  clear-
ances listed on this page.
7) We recommend that you plan your installa-
tion on paper using exact measurements
for clearances and floor protection before
actually  installing  this  appliance.  Have  a
authorized  inspector,  dealer,  or  installer
review  your  plans  before  installation.
Note: For  Exterior  Flue    Termination
Locations  see  page  12.
.
INSTALLATION
A) P121 - See Thru
B) P131 - Pier
C) P121LC - Left Corner
D) P121RC - Right Corner