Venting Arrangements - Horizontal 
Terminations
This diagram shows all allowable combinations of vertical runs with 
horizontal terminations, using one 45° and one 90° elbow (two 45º
 
elbows equal one 90° elbow).
Note:  Must use optional fl ue adapter (Part # 770-994) when using 
Rigid Pipe. 
•  
Maintain clearances to combustibles.
•  
Horizontal vent must be supported every 3 feet.
•  
Firestops are required at each fl oor level and whenever passing 
through a wall.
A vent guard should be used whenever the termination is lower than the 
specifi ed minimum or as per local codes.
Note:  FPI Direct Vent System (Flex) is only approved for horizontal 
terminations.
Please refer to Page 11 (Exterior Vent Terminations) 
for additional guidelines on vent locations.
P48 Gas Fireplace