Regency U32-LP4 User Manual

Page of 40
7
U32-4 FPI Direct Vent Gas Insert
A
B
D
E
C
MANUFACTURED 
MOBILE HOME 
ADDITIONAL 
REQUIREMENTS
1)  Ensure that structural members are not cut 
or weakened during installation.
2)  Ensure proper grounding using the #8 
ground lug provided.
3)  Appliance must be anchored to the fl oor 
with the supplied anchoring methods. 
MATERIALS REQUIRED
No electrical power supply is required for the gas 
control to operate.  A 120 Volt AC power cord is 
hooked up to the fan.  Plug  the 3 wire cord into 
a suitable receptacle.  Do not cut the ground 
terminal off under any circumstances.
  When 
connected with 120 volts, the appliance must be 
electrically grounded in accordance with local 
codes, current version of CSA C22.1 (in Canada) 
or in the absence of local codes, with the National 
Electrical Code ANSI/NFPA 70-1987.
INSTALLATION
INSTALLATION 
CHECKLIST
Before installing vent system ensure that the 
damper plate is open and secure to prevent the 
damper plate from falling down and crushing 
the liner.
The FPI Gas Insert is installed as listed.
1)  Check all clearances to combustibles, (Refer 
to sections "Minimum Fireplace Dimensions 
and Clearances to Combustibles)
2)  Make the gas connection. (Refer to section 
"Gas Connection")
3)  Install the 3" flue liner to the sliding 
connector plate. (Refer to section "Flue 
Liner Installation.")
4)  Slide the unit half way into the fi replace.
5)  Pull the vent connector plate through the 
tapered brackets and fasten to the front plate. 
Refer to section "Flue Liner Installation.")
6)  Slide the unit fully into the fi replace. 
7)  Test gas pressure (Refer to section "Gas 
Pipe Pressure Testing"). Check aeration 
system (Refer to section "Gas Insert Aeration 
System").
8)  Install standard and optional features.  Refer 
to the following sections: 
 a. 
Brick 
Panel
 
b. Lot Set 
 c. 
Faceplate 
Trim 
 
d. Standard Flush Door
 e. 
Flush 
Trim
 
f.  Double Screen Door
 g. 
Flush 
Louvers
 h. 
Bay 
Louvers
 
i.  Bay Door
 j. 
 
Bay 
Trim
 
k. Full Screen Doors
 l. 
 
Hampton 
Cast 
Faceplate 
 m. 
Hampton 
Cast 
Grills
 
n. The Kensington Front  
 o. 
Wall 
Thermostat
 
p.  Remote Control
9)  Final check: Before leaving this unit with the 
customer, the installer must ensure that the 
appliance is fi ring correctly. This includes:
 
a)  Clocking the appliance  to ensure the 
correct fi ring rate.
 
b)  Adjusting the primary air, if required, to 
ensure that the fl ame does not carbon.  
See "Gas Insert Aeration System" 
section.
 
c)  Ensuring that the appliance is venting 
correctly.
 
MINIMUM FIREPLACE 
DIMENSIONS
The minimum fi replace clearances & dimensions 
for the FPI gas insert are shown in the following 
diagrams:
Diagram 1
Combustible Mantel Clearances 
with Bay & Flush Louvers in 
Masonry and Factory Built 
Fireplace Installation
Diagram 2
CLEARANCES TO 
COMBUSTIBLES
Minimum Clearances to Combustibles
                             From Unit             
Sides
 
A 
10" / 255 mm
Ceiling 
B 
47.5" / 1205 mm
Mantel 
C  
see Dia. 2 & 3
        From Standard Surround (26" x 40")
Sides
 
D 
4" / 100 mm
Ceiling 
E 
41.5" / 1055 mm
Mantel 
 
see Dia. 2 & 3
Max. Mantle Depth 
12" / 305 mm 
 
 
(see Dia. 2)
Hearth Height 
H 
0" / 0 mm
Hearth Depth 
I 
16" / 405 mm
Hearth Width 
J 
40" / 1015 mm
Max Lentil 
Bar Depth
A
Height
B
Depth
C
Width
(rear)
D
Width
(front)
E
Regency 
Countour 
Faceplate
9"
22"
14"
22-1/2"
26-1/2"
Regency 
Molded 
Faceplate
10"
22"
15"
22-1/2"
29"
Palace 
Front
10"
22"
15"
22-1/2"
29"
Hampton 
Cast 
Faceplate
9"
22"
14"
22-1/2"
26-1/2"