VENTING ARRANGEMENTS 
HORIZONTAL TERMINATION (FLEX)
Regency
®
 Direct  Vent System 
These venting systems, in combination with the L900, have been tested and listed as a direct vent system by Warnock Hersey. The location of the 
termination cap must conform to the requirements in the Vent Terminal Locations diagram from the "Exterior Vent Termination Locations" section.
FPI Direct Vent (Flex) System Termination Kits include all the 
parts needed to install the L900 using a fl exible vent.
8” dia.
Flue pipe
5” dia. flue pipe
spring spacer
Termination Cap
AstroCap XL
TM
(Part #946-623/P)
Vent Guard - if required*
(Part #946-506/P)
Wall Thimble
(Mandatory in all
Horizontal Terminations)
Vinyl Siding
Standoff
Notes: 
1)  Liner sections should be continuous without any joints 
or seams.
2)  Only Flex pipe purchased from FPI may be used for Flex 
installations.
3)  Horizontal vent must be supported every 3 feet.
4)  A wall thimble is mandatory for all horizontal terminations 
due to high temperatures.
 
FPI Kit # 
Length 
Contains:
#946-618
6 Feet
1) 
8” fl exible liner (Kit length)
2) 
5” fl exible liner (Kit length)
3) spring 
spacers 
(3)
4) thimble 
(2)
5) 
AstroCap termination cap (1)
6) screws 
(12)
7) 
tube of Mill Pac (1)
8) plated 
screws 
(8)
9) 
S.S. screws #8 x 1-1/2” drill point, (4)
10)  vinyl siding standoff
#946-616
10 Feet
 
* A Vent Guard is required when the AstroCap 
is installed above grade at 7 feet or lower.