Regency L900-LP User Manual

Page of 56
Regency
®
 L900 Direct Vent Gas Fireplace
28
INST
ALLA
TION
CONVERSION KIT #546-969 FROM NG TO LP
LP Conversion Kit Contains:
Qty.   Part # 
 
Description
1  
    910-462  
LP Conversion Coil
1  
    904-573  
Cable Tie
1      910-037  
LP Pilot Orifi ce
1      904-641  
Orifi ce #50 (back)
1      904-241  
Orifi ce #56 (front)
1      904-529  
Allen Key
1      918-590  
LP Conversion Decal
1      908-528  
Red Propane Label
1      918-608  
Instruction Sheet
1)
  Remove the glass door.
 
a. Release the 2 door latches on the left  
    and right side at the top of the fi rebox.
  b. Swing the door out from the top and  
release the hinges on the left and right 
side of the door by lifting them up.
Latch
  c.   Place the door on a soft surface to prevent 
scratching.
Hinge
Door
Latch Location
2)   
Remove the grate by undoing the 2 screws 
on the right and left side.
3) 
Remove the front burner by removing the  
      screw.
Grate
Front Burner
Front Burner Removed
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER, IF IN DOUBT DO NOT DO THIS CONVERSION!!
LP Conversion instructions for BEFORE UNIT INSTALLATION.
4)  
Remove the back burner by removing the  
       screw.
Back Burner
5)  
Remove the rear log stand by removing  
       the 4 screws.
Rear Log Stand
INSTALLATION