Regency L900-LP User Manual

Page of 56
Regency
®
 L900 Direct Vent Gas Fireplace
39
OPERA
TION
OPERATING 
INSTRUCTIONS
1)  Read and understand these instructions 
before operating this appliance.
2)  Check to see that all wiring is correct and 
enclosed to prevent possible shock.
3)  Check to ensure there are no gas leaks.
4)  Make sure the glass in the door frame is 
properly positioned. Never operate the 
appliance with the glass removed.
5)  Verify that the venting and cap are 
unobstructed.
6)  Ensure that the brick panels are installed.
7)  Verify log placement. If the pilot cannot be 
seen when lighting the unit, the logs have 
been incorrectly positioned.
8)  The unit should never be turned off, and on 
again without a minimum of a 60 second 
wait.
IMPORTANT Gas on/off knob cannot be 
turned from "PILOT" to "OFF" unless it is 
partially depressed.
Ensure that the 3 way switch on the manual 
control panel is in the "Remote" position. 
The manual control panel is located on the left 
hand side of the fi rebox behind the left side 
exterior brick panel.
During the fi rst  few  fi res,  a  white  fi lm 
may develop on the glass front as part of 
the curing process. The glass should be 
cleaned after the unit has cooled down 
or the fi lm will bake on and become very 
diffi cult to remove. Use a non-abrasive 
cleaner and DO NOT ATTEMPT TO CLEAN 
THE GLASS WHILE IT IS HOT.
Only when the pilot holds, without pressure 
being applied to the control knob, resecure the 
glass door to the unit. The unit must not be 
operated with the glass door removed. 
IMPORTANT
To ignite or reignite the pilot, you 
must fi rst remove the glass door. 
LIGHTING 
PROCEDURE
The FIRST FIRE in your heater is part of the paint 
curing process. To ensure the paint is properly 
cured, it  is  recommended you  burn your fi replace 
for at least four (4) hours the fi rst time.
When fi rst operated, the unit will release an 
odour caused by the curing of the paint and the 
burning off of any oils remaining from manufac-
turing. Smoke detectors in the house may go off 
at this time. Open a few windows to ventilate 
the room for a couple of hours. The glass may 
require cleaning.
NOTE:  The main burner will always start on 
"HIGH" and resume it's last setting after 
20 seconds of operation.
NOTE: When the glass is cold and the appliance 
is lit, it may cause condensation and fog 
the glass. This condensation is normal 
and will disappear in a few minutes as 
the glass heats up.
DO NOT ATTEMPT TO CLEAN THE 
GLASS WHILE IT IS STILL HOT
!
FIRST FIRE
DO NOT BURN THE APPLIANCE 
WITHOUT THE GLASS FRONT IN 
PLACE.
3-way Switch
MATCHING REMOTE 
HANDSET & CONTROL 
BOX ID CODE
The Remote Control Handset has a set of 
unique ID codes that is pre-programmed into its 
memory. This set of ID codes helps to differenti-
ate one Remote Control Handset from another 
so that only the control box with a matching ID 
code will respond to the appropriate Remote 
Control Handset.
To ensure the remote control is matched to 
the receiver correctly, please follow the steps 
below: 
1.  Ensure that the Remote Control and the 
3-way switch located at the appliance are 
both in the OFF position.
2.  Ensure that the pilot is lit and the pilot 
control knob is in the ON position on the 
appliance.
3.  Install the 2 x AAA alkaline batteries into the 
Remote Control.
4.  Unplug and re-plug the power cord. The 
power cord is located on the left hand side 
of the appliance and will be plugged into the 
receptacle.
5.  Switch the 3-way switch located on the ap-
pliance to the REMOTE position.
6.  Press and hold the PROG and FAN buttons 
simultaneously for up to 20 seconds. During 
this time, the remote will display LC while it 
is transmitting codes to the receiver. Once 
it is successfully transmitted, one will hear 
the solenoid click and the burners will come 
on. If is does not work the fi rst time, repeat 
steps 1 - 6. 
7.  Release both the PROG and FAN buttons. 
The remote will revert back to normal, but 
the burner will still be on.
8.  Press the ON/OFF button on the remote 
control 2 times to turn the burner off.
9.  The remote control is now programmed to 
the receiver and the appliance can now be 
operated with it.
The control box will only learn the Remote ID 
codes during the fi rst 30 seconds after power 
is applied and will ignore this special command 
from the Remote after the fi rst 30 seconds. 
NOTE: This must only be performed by a quali-
fi ed installer.
 
OPERATING INSTRUCTIONS